Article 200-285 Part08

This comprehensive quiz contains 50 questions carefully selected from the National Electrical Code (NEC) Articles spanning 200 through 285. These articles cover a broad spectrum of vital topics related to electrical installations within this section of the code.

The questions in this quiz are chosen randomly to provide a thorough assessment of your knowledge across these essential NEC articles. While we strive for a diverse set of questions, some fundamental principles may be revisited in different contexts due to their relevance to multiple sections within this range. This approach ensures a robust evaluation of your understanding.

We encourage you to actively participate and provide feedback. If you identify any issues or have suggestions for improving the quiz questions, please report them. Your contributions are invaluable in helping us maintain the accuracy and effectiveness of these learning resources.

Think about the NEC’s requirement for grounding the neutral conductor at the service entrance.

1 / 50

Is it true that when grounding service-entrance equipment, the identified neutral conductor is the conductor that is required to be grounded, as per NEC 250.26?

Think about the common limitation for overcurrent protection when dealing with continuous loads to prevent overheating.

2 / 50

Unless the overcurrent device and the equipment that encloses it, such as a panelboard or enclosure, is rated at 100% of its rating, continuous loads are limited to not more than __% of the rating.

Think about the NEC’s limitation on the number of service disconnects allowed for a building.

3 / 50

NEC 230.71 permits no more than ___ disconnects to serve as the building service disconnecting means.

Think about the NEC article that deals specifically with grounding and bonding requirements for electrical systems.

4 / 50

The NEC covers grounding and bonding in several articles, but the primary coverage is found in Article ___.

Think about the point at which service conductors are provided with overcurrent protection according to NEC.

5 / 50

Is it true that service conductors do not have overload protection until they reach the main service disconnecting means overcurrent protection?

Consider the standard interrupting rating for circuit breakers.

6 / 50

Every breaker having an interrupting rating other than _____ is to have its interrupting rating shown on the breaker.

Continuous load limits are specified unless equipment is rated for full load.

7 / 50

Unless the overcurrent device and the equipment that encloses it, such as a panelboard or enclosure, is rated at 100% of its rating, continuous loads are limited to not more than __% of the rating.

Consider the NEC section that addresses the proper sizing of bonding conductors based on the overcurrent protection device.

8 / 50

The bonding conductor(s) or jumper(s) shall be sized in accordance with which NEC section?

Consider the areas where placing overcurrent devices could create safety hazards, such as potential fire risks or limited access during emergencies.

9 / 50

Additional major concerns regarding the location of overcurrent devices include that they are not permitted to:

Think about the limitation imposed on fastened-in-place appliances when sharing a circuit with other appliances.

10 / 50

An appliance is fastened in place, and other cord-and-plug-connected appliances are connected to a 20-ampere branch circuit. What is the maximum allowable load for the appliance that is fastened in place?

Look for the industry-standard color-coding used to identify wires in a 277/480V system.

11 / 50

What are the identifying colors for a 277/480V system?

Consider the fact that short-circuit and ground-fault currents can deviate significantly from the normal operating current and may not always exceed it.

12 / 50

Short-circuit and ground-fault currents have the following characteristics:

  • They flow outside the normal current path.
  • They may be greater than the normal current.
  • They may be less than the normal current.

Think about the relationship between the conductor’s ampacity and the need for properly sized overcurrent protection to prevent overheating.

13 / 50

Overcurrent protection is sized according to the ampacity of a conductor.

Look for the article that covers grounding and bonding in detail, ensuring electrical systems are safe and stable.

14 / 50

The NEC covers grounding and bonding in several articles, but the primary coverage is in Article ____.

Think about the common maximum ampacity allowed for 12 AWG copper conductors.

15 / 50

The maximum overcurrent protection for 12 AWG copper conductors is _______ amperes.

Think about the maximum current that a 20-ampere circuit can safely supply to a single appliance without overloading.

16 / 50

A 20-ampere branch circuit is not permitted to serve a single appliance with a rating greater than ____ amperes.

Think about the standard interrupting rating that does not require special marking, and when it must be shown on the breaker.

17 / 50

Every breaker having an interrupting rating other than _____ is required to have its interrupting rating shown on the breaker.

Consider the article that focuses on protecting conductors and circuits from excessive current using devices like circuit breakers and fuses.

18 / 50

NEC Article ___ sets forth the requirements for overcurrent protection of conductors and for overcurrent devices.

Think about the common protective devices used in feeders and branch circuits to ensure quick response in overcurrent situations.

19 / 50

Fast-acting, current-limiting fuses and circuit breakers are generally used for feeders and branch circuits.

Consider the safety and accessibility requirements for building occupants in case they need to reset or disconnect their circuits.

20 / 50

As long as a qualified electrician has access to the overcurrent devices for the branch circuit, it does not matter if the commercial building’s tenant has access to them.

Think about where the neutral conductor should be bonded to the panel enclosure and when it is not allowed.

21 / 50

Is it true that in feeder panelboards, the neutral conductor is not connected to the panel enclosure?

Think about which conductor is required to be grounded to ensure a stable electrical system and protection against electrical faults in service-entrance equipment.

22 / 50

According to NEC 250.26, the identified neutral conductor is the conductor required to be grounded when grounding service-entrance equipment. Is this statement true or false?

Think about the NEC’s requirement for a low-impedance path to clear faults and whether the earth alone qualifies as such a path.

23 / 50

Is it true that when grounding service-entrance equipment, the earth is not considered an effective ground-fault current path, as per NEC 250.4(A)(5)?

Think about the NEC requirement that involves grounding conductive materials that enclose electrical equipment to protect against electrical faults.

24 / 50

Which term refers to normally non-current-carrying conductive materials enclosing electrical conductors or equipment, which must be connected to earth to limit the voltage to ground?

Consider the standard ampere ratings that are commonly listed in the NEC for circuit breakers.

25 / 50

A 55A circuit breaker is considered a standard ampere rating.

Consider the NEC rules regarding the number of service disconnects permitted for a service or service-entrance conductors.

26 / 50

Is it true that two to six service disconnects are permitted for each service allowed by 230.2 or for each set of service-entrance conductors allowed by 230.40, Exception No. 1, 3, 4, or 5?

Consider the ampacity limits for 12 AWG copper conductors.

27 / 50

The maximum overcurrent protection of 12 AWG Copper conductors is:

Consider if overcurrent devices can be used in specific applications like motor overload protection.

28 / 50

Overcurrent devices are permitted to be used in ground conductors when used for motor overload protection.

Think about the point at which service conductors receive overcurrent protection in an electrical system.

29 / 50

Is it true that service conductors do not have overload protection until they reach the main service disconnecting means overcurrent protection?

Consider the relationship between conductor ampacity and overcurrent protection.

30 / 50

Overcurrent protection is sized according to the ampacity of a conductor.

Consider the NEC’s definition of continuous loads, which relates to loads that are expected to run for an extended period.

31 / 50

A circuit breaker is not permitted to be loaded to more than 80% of its current rating for loads that are likely to be on for __ hours or more.

Consider the NEC’s requirements for making secure and approved connections for grounding electrode conductors.

32 / 50

Is it true that the grounding electrode conductor is required to be tightly connected using proper lugs, connectors, clamps, or other approved means?

Consider the 80% rule, which limits the maximum load of an appliance connected to a branch circuit to ensure safety and avoid overloading the circuit.

33 / 50

A 20-ampere branch circuit is not permitted to serve a single appliance with a rating greater than ____ amperes.

Consider the NEC section that addresses bonding requirements for metal gas piping to ensure safety.

34 / 50

The bonding of metal gas piping is required by which NEC section?

Think about the term that refers to grounding non-current-carrying parts of electrical systems for safety purposes.

35 / 50

Which term is defined as normally non-current-carrying conductive materials enclosing electrical conductors or equipment, or forming part of such equipment, that shall be connected to earth to limit the voltage to ground on these materials?

Consider the NEC table that provides guidance for grounding electrode conductor sizing based on the size of the ungrounded conductors.

36 / 50

Which NEC table is referred to when sizing grounding electrode conductors for services, separately derived systems, and the building or structure disconnecting means?

Consider the standard percentage used to ensure safety for continuous loads that operate for long periods, as outlined by the NEC.

37 / 50

Unless the overcurrent device and its enclosure, such as a panelboard, is rated for operation at 100% of its rating, continuous loads (operating for three hours or more) are limited to no more than __% of the rating.

Focus on the fact that only the overcurrent device must be rated for 100% operation, not the enclosure.

38 / 50

Continuous loads are limited to 80% of the overcurrent device’s rating unless the device and enclosure are rated for 100% operation, according to NEC Articles 210.19(A)(1) and 215.2(A)(1).

Focus on the article that discusses branch circuits and specific configurations like multiwire circuits.

39 / 50

NEC _______ contains the requirements for multiwire branch circuits.

Consider the need for occupants to have quick access to the circuit breakers that control their specific areas in a commercial building.

40 / 50

The occupants of various businesses in a commercial building must have access to the overcurrent devices for their branch circuits, as per NEC 240.24(B).

Think about commonly used fuse sizes in residential and small commercial electrical systems.

41 / 50

A standard fused disconnect has an ampere rating of 30 amperes.

Think about the NEC section that governs the sizing of bonding conductors and grounding conductors to ensure they are appropriately rated for their application.

42 / 50

The bonding conductor(s) or jumper(s) must be sized in accordance with which NEC section?

Consider the conditions under which the metal frame of a building may be used as part of the grounding electrode system.

43 / 50

Is it true that the metal frame of a building is permitted to be used as a grounding electrode conductor?

Think about the NEC limit on the number of services disconnects that are permitted for a building.

44 / 50

According to NEC 230.71, no more than how many disconnects are permitted to serve as the building service disconnecting means?

Consider the NEC’s requirement for maintaining a low-impedance path to safely carry fault current and prevent it from flowing on unintended metal objects.

45 / 50

Is it true that some of the fault current might flow on sheet metal ductwork, metal water, or metal gas piping, which is why the NEC emphasizes keeping the impedance of the ground-fault current path as low as possible?

Consider the NEC’s requirements for grounding in single-phase transformer installations, particularly where the center tap provides a neutral.

46 / 50

Is it true that for single-phase transformers, the center tap of the transformer secondary is required to be grounded?

Consider the NEC table that provides sizing information for equipment grounding conductors, particularly when overcurrent protection is present.

47 / 50

Which NEC table is referred to when selecting equipment grounding conductors when there is overcurrent protection ahead of the conductor supplying the equipment?

Consider the devices that are designed to interrupt excessive current in electrical circuits to prevent damage or fire.

48 / 50

Two types of overcurrent protective devices that are commonly used are _______________.

Consider the standard ampere ratings that are commonly listed in the NEC for both fuses and nonadjustable circuit breakers.

49 / 50

Select all the standard ampere ratings for fuses and nonadjustable circuit breakers.

Think about why grounding is important for stability and safety in transformer secondary circuits.

50 / 50

Is it required to ground the center tap of a single-phase transformer’s secondary?