Article 400-490 Part06

This quiz consists of 50 carefully selected questions covering NEC Articles 400 through 490, which provide critical guidelines for flexible cords and cables (Article 400), switchgear and control equipment (Article 409), and installations operating above 1000 volts (Article 490). These sections of the National Electrical Code focus on safety, material specifications, and proper installation practices.

The randomly generated questions ensure a thorough assessment of your understanding, reinforcing key principles related to permitted uses of flexible cords, ampacity ratings, industrial control panels, and high-voltage equipment requirements. Some topics may reappear in different contexts to strengthen comprehension and application.

Your feedback is invaluable! If you notice any discrepancies or have suggestions for improvement, please report them. Your insights help maintain the accuracy and effectiveness of this learning tool.

Consider the power rating specifications set by the NEC for portable generators regarding safety features.

1 / 50

Receptacle outlets that are a part of a ______ kW or smaller portable generator shall have listed ground-fault circuit-interrupter protection (GFCI) for personnel integral to the generator or receptacle.

Consider the maximum allowable lengths for appliance cords to ensure safe installation and operation.

2 / 50

The length of the cord for a built-in dishwasher shall not be longer than ______ ft, measured from the face of the attachment plug to the plane of the rear of the appliance.

Consider the characteristics of the plug and receptacle combination that allow it to function safely as a disconnecting means.

3 / 50

For cord-and-plug- (or attachment fitting-) connected appliances, a(n) ______ plug (or attachment fitting) and receptacle combination shall be permitted to serve as the disconnecting means.

Consider the types of equipment commonly used in public areas that may require GFCI protection to ensure personnel safety.

4 / 50

______ rated 250V or less and 60A or less, single- or three-phase, shall be provided with GFCI protection for personnel.

Consider the NEC requirements regarding the marking of electrical equipment in different types of installations.

5 / 50

All switchboards, switchgear, and panelboards supplied by a feeder(s) in ______ shall be permanently marked to indicate each device or equipment where the power supply originates.

Consider the NEC guidelines regarding where electric space-heating cables can be safely installed in relation to walls.

6 / 50

Electric space-heating cables shall not be installed ______ walls.

Consider the specifications for the type of labeling required by the NEC for electrical equipment.

7 / 50

The label required for switchboards, switchgear, and panelboards (408.4(B)) must be permanently affixed, sufficiently durable to withstand the environment involved, and handwritten.

Think about the safety feature required for disconnecting a transformer during maintenance.

8 / 50

Transformers located in a remote location must have a disconnecting means that is __________________.

Use the NEC guideline for selecting overcurrent protection devices for single-phase motors based on their full-load current.

9 / 50

A single-phase motor must have a dual-element (time-delay) fuse rated at ____________ of its rated full-load current.

Consider the requirements for the classification and certification of storage batteries to ensure safety and compliance.

10 / 50

Storage batteries, other than lead-acid batteries, and battery management equipment shall be ______.

Think about the rating required for switches used to control a motor’s specific load to ensure safe operation.

11 / 50

For most installations, a motor circuit switch that controls a motor must be ____.

Consider the specific locations where electric space-heating cables are prohibited by the NEC.

12 / 50

Electric space-heating cables shall not be installed ______ walls.

Consider the NEC regulations regarding safe distances between heating elements and electrical boxes to prevent overheating and ensure safety.

13 / 50

The minimum clearance between the heating elements of electric space-heating cables installed in ceilings and outlet boxes and junction boxes used for mounting surface luminaires shall not be less than ______ in.

Consider the conditions under which range hoods can be safely connected using a cord and plug.

14 / 50

Range hoods shall be permitted to be cord-and-plug-connected with a flexible cord identified as suitable for use on range hoods in the installation instructions of the appliance manufacturer, provided ______.

First, calculate the full-load current for both the primary and secondary sides. Then apply NEC overcurrent protection rules and select the appropriate conductor sizes and protection devices.

15 / 50

What are the primary and secondary overcurrent protection devices and conductor sizes for a 75 kVA three-phase, 480/208Y/120 transformer?

Consider the guidelines provided by manufacturers regarding the installation of battery connections involving different metals.

16 / 50

Where mating dissimilar metals, antioxidant material suitable for the battery connection shall be used where ______ by the battery manufacturer.

Consider the NEC guidelines regarding cord connection for luminaires and the types of cords that are permissible.

17 / 50

Luminaires that require adjusting or aiming after installation can be cord connected without an attachment plug, provided the exposed cord is suitable for hard usage or extra-hard usage and is not longer than necessary for maximum adjustment.

Consider the necessary clearances specified by the NEC in relation to cabinetry and heating cables.

18 / 50

Electric space-heating cables shall not be installed over cabinets whose clearance from the ceiling is less than the minimum ______ dimension of the cabinet to the nearest cabinet edge that is open to the room or area.

Consider the safety regulations regarding combustible materials in areas where electrical appliances are installed.

19 / 50

Any combustible ceiling finish that is exposed between the edge of a ceiling-suspended (paddle) fan canopy or pan and an outlet box, and that has a surface area of ______ sq in. or more, shall be covered with noncombustible material.

Consider the standards required for GFCI protection in portable generators to ensure safety and compliance.

20 / 50

Unbonded 15 kW or smaller portable generators with both 125V and 125/250V receptacle outlets shall have ______ GFCI protection for personnel integral to the generator or receptacle on all 125V, 15A and 20A receptacle outlets.

Think about the ways to ensure that receptacles for cord-connected appliances are protected from damage.

21 / 50

An in-sink waste disposer can be cord-and-plug-connected, but receptacles shall be ______ to protect against physical damage to the flexible cord.

Consider the NEC requirements regarding the placement of receptacles in relation to built-in appliances.

22 / 50

The receptacle for a built-in dishwasher shall be located ______ occupied by the dishwasher.

Consider the conditions under which space-heating cables are allowed to extend into different areas according to the NEC.

23 / 50

Electric space-heating cables shall be permitted to extend beyond the room or area in which they ______.

Focus on which conductors require disconnection to ensure system safety and compliance.

24 / 50

A disconnecting means must be provided for all ____________ derived from a stationary battery system with a voltage over 60 volts DC.

Consider the types of locations where tamper-resistant receptacles are mandated for safety.

25 / 50

Nonlocking-type 125V and 250V, 15A and 20A receptacles installed in ______ shall be listed as tamper-resistant.

Consider the amperage ratings of receptacle outlets that require GFCI protection for safety compliance.

26 / 50

Bonded 15 kW or smaller portable generators shall be provided with GFCI protection on all 125V, ______ receptacle outlets.

Consider what components are most susceptible to damage in the installation of built-in appliances.

27 / 50

Receptacles for built-in dishwashers and trash compactors shall be located to protect against physical damage to the ______.

Think about the rules concerning the installation of space-heating cables and their allowed extensions.

28 / 50

Electric space-heating cables shall be permitted to extend beyond the room or area in which they ______.

Consider the NEC guidelines regarding the positioning of receptacles in relation to the appliances they serve.

29 / 50

The receptacle for a trash compactor shall be located ______ occupied by the appliance.

Control circuit conductors protected by motor branch circuit protection devices are allowed higher overcurrent protection ratings than general-purpose circuits.

30 / 50

What is the maximum size overcurrent protection device required to protect #14 AWG conductors used for the pump motor control circuit that is protected by a motor branch circuit protection device and extends beyond the enclosure?

Think about the term commonly used for a box designed for hanging or movable connections.

31 / 50

What is a box containing pendant- or flush-mounted receptacles attached to a multiconductor cable via strain relief or a multipole connector called?

Consider the voltage limits set by the NEC specifically for lighting systems exposed to wet conditions to ensure safety.

32 / 50

Article 411 covers lighting systems and their associated components operating at no more than ______ AC or ______ DC where wet contact is likely to occur.

Use the NEC requirement to size overcurrent protection devices for phase converters based on their full-load current (FLA).

33 / 50

A phase converter with a nameplate input rating of 100 FLA, protecting a variable load, must have overcurrent protection set at _______________________.

Think about the positioning of luminaires in relation to their power source and how this impacts safety and accessibility.

34 / 50

An electric-discharge or LED luminaire or listed assembly can be cord connected if the luminaire is located ______ the outlet, the cord is visible for its entire length except at terminations, and the cord is not subject to strain or physical damage.

Think about the safety considerations and specific applications required for receptacles installed in kitchen areas.

35 / 50

Receptacles in or on countertop surfaces or work surfaces shall not be installed ______, unless they are listed for countertop or work surface applications.

Consider the necessary standards that ensure safety and compliance for electrical components integrated into cover plates.

36 / 50

A flush device cover plate that additionally provides a night light and/or Class 2 output connector(s) shall be ______ such that the night light and/or Class 2 circuitry is integral with the flush device cover plate.

Consider the conditions under which a plug and receptacle connection can safely serve as a disconnecting means for household appliances.

37 / 50

For cord-and-plug-connected household electric ranges, an attachment plug and receptacle connection at the rear base of the range can serve as the disconnecting means if it is ______ and meets the intent of 422.33(A).

Consider the locations where the installation of electric space-heating cables could pose safety hazards.

38 / 50

Electric space-heating cables shall not be installed ______.

Consider the implementation dates for regulations regarding GFCI protection in portable generators.

39 / 50

If the 15 kW or smaller portable generator was manufactured or remanufactured prior to ______, listed cord sets or devices incorporating listed GFCI protection for personnel identified for portable use shall be permitted.

Consider the types of receptacle assemblies that are specifically designed for safe use in areas prone to moisture and other hazards.

40 / 50

Receptacle assemblies and ______ receptacle assemblies listed for work surface or countertop applications shall be permitted to be installed in work surfaces.

Think about where the operational current information is typically provided for motors.

41 / 50

Conductor ampacity for AC adjustable voltage motors shall be based on the maximum operating current marked on the _______________________________.

Consider the maximum voltage limits set by the NEC for specific lighting systems to ensure safety and compliance.

42 / 50

Article 411 covers lighting systems and their associated components operating at no more than ______ AC or ______ DC.

Think about the importance of making all disconnecting means easily identifiable for safety purposes.

43 / 50

When heating equipment is supplied by more than one source, feeder, or branch circuit, the disconnecting means must be ______________.

Consider the environments where tamper-resistant receptacles are mandated for enhanced safety.

44 / 50

In dwelling units, all nonlocking-type 125V and 250V, 15A and 20A receptacles installed ______ shall be listed as tamper-resistant.

Consider the motor ratings that determine when a disconnecting means is required for motor-operated appliances.

45 / 50

For permanently connected motor-operated appliances with motors rated over ______, a switch or circuit breaker located within sight from the motor-operated appliance, or capable of being locked in the open position in compliance with 110.25, can serve as the appliance disconnect.

Consider both acceptable methods for ensuring snap switches are properly grounded and part of an effective fault-current path.

46 / 50

Snap switches are considered part of an effective ground-fault current path when _______________.

Consider the types of equipment that are commonly used in public areas or where water exposure is likely, which necessitate GFCI protection.

47 / 50

______ rated 250V or less and 60A or less, single- or three-phase, shall be provided with GFCI protection for personnel.

Consider the maximum allowable lengths for appliance cords to ensure safe operation and compliance with electrical codes.

48 / 50

The length of the cord for a trash compactor shall not be longer than ______ ft, measured from the face of the attachment plug to the plane of the rear of the appliance.

Consider the conditions under which GFCI protection is waived for certain configurations of receptacle outlets on portable generators.

49 / 50

GFCI protection for 15 kW or smaller portable generators shall not be required where the 125V receptacle outlet(s) is interlocked such that it is not available for use when any 125/250V receptacle(s) is in use.

Consider the maximum allowable rating for appliances to determine when the branch-circuit overcurrent device can serve as the disconnecting means.

50 / 50

For permanently connected appliances rated at not over ______ or 1/8 hp, the branch-circuit overcurrent device shall be permitted to serve as the disconnecting means where the switch or circuit breaker is within sight from the appliance or is lockable in accordance with 110.25.