eep April 10, 2025 NEC 500-590 NEC Quizzes Report a question What’s wrong with this question? You cannot submit an empty report. Please add some details. 0% Article 500-590 Part05 This quiz consists of 50 carefully selected questions covering NEC Articles 500 through 590, which provide essential guidelines for hazardous locations (Article 500), special occupancies (Article 525), and temporary installations (Article 590). These sections of the National Electrical Code focus on safety, classification of hazardous areas, material requirements, and proper installation practices for environments with heightened risks. The randomly generated questions ensure a thorough assessment of your understanding, reinforcing key principles related to explosive atmospheres, grounding requirements, temporary wiring regulations, and specific occupancy considerations. Some topics may reappear in different contexts to strengthen comprehension and application. Your feedback is invaluable! If you notice any discrepancies or have suggestions for improvement, please report them. Your insights help maintain the accuracy and effectiveness of this learning tool. Division 1 demands strict motor design standards. 1 / 50 What is the requirement for motors in Class II, Division 1 locations (502.125(A))? a. Motors must be explosionproof. b. Motors must be identified for the location or totally enclosed pipe-ventilated. c. General-purpose motors are allowed. d. Motors can use open designs with guards. Incorrect. Motors in Division 1 must meet stricter requirements. Correct! Motors must be identified for the location or use specific enclosed designs. Motors must either be identified for use in Class II, Division 1 or use totally enclosed pipe-ventilated designs to prevent dust accumulation. Grounding ensures safety in all hazardous locations. 2 / 50 What is the grounding requirement for wiring systems in Class II locations (502.30)? a. Grounding must comply with Article 250 requirements. b. No grounding is needed in Division 2. c. Grounding is optional for low-voltage systems. d. Only required for portable equipment. Incorrect. Grounding compliance with Article 250 is mandatory. Correct! Wiring systems must comply with Article 250 grounding requirements. All wiring systems in Class II locations must be grounded per Article 250 for safe operation. Grounding prevents static buildup and ensures safety. 3 / 50 What grounding requirements apply in Class III locations (503.30)? a. Only motors and generators require grounding. b. Grounding is optional for Division 2 locations. c. Grounding applies only to outdoor installations. d. All wiring systems and equipment must comply with Article 250. Incorrect. Grounding compliance with Article 250 is mandatory. Correct! Grounding ensures safety and compliance with Article 250. All wiring and equipment in Class III locations must be grounded in accordance with Article 250 to prevent ignition risks. Enclosures must be verified to meet installation requirements. 4 / 50 What testing is required for explosionproof enclosures after installation (501.5)? a. Routine pressure testing every 5 years. b. Visual inspection only. c. No testing is required for listed enclosures. d. Field inspection and verification of proper assembly. Incorrect. Field inspections are mandatory for safety. Correct! Field verification ensures compliance with listing requirements. Explosionproof enclosures must be inspected to ensure they are correctly assembled and comply with the listing requirements after installation. Nonincendive means incapable of causing ignition. 5 / 50 How are nonincendive circuits defined in Class I, Division 2 (501.10(B) (3))? a. Circuits sealed with non-metallic covers. b. Circuits with energy levels too low to ignite hazardous atmospheres. c. Only high-resistance circuits. d. Circuits incapable of producing sparks. Incorrect. Nonincendive circuits operate at inherently safe energy levels. Correct! These circuits prevent ignition by limiting energy. Nonincendive circuits limit energy to levels insufficient to ignite gases or vapors, ensuring safe operation in Division 2 locations. Dust-tight construction ensures heaters do not ignite nearby dust. 6 / 50 How must heaters be constructed in Class II, Division 2 locations (502.135(B))? a. They must be dust-tight or otherwise identified for the location. b. They must include built-in explosionproof thermostats. c. Heaters require no special construction. d. Only radiant heaters are permitted. Incorrect. Dust-tight or identified heaters are required in Division 2. Correct! Heaters must be dust-tight or identified for the location. Electrically heated equipment must be dust-tight or specifically identified for the hazards in Division 2 locations. Dust layers increase ignition risk. 7 / 50 What is the required surface temperature of equipment in Class II, Division 1 locations with dust layers (500.8(D)(2))? a. Below the ignition temperature of the dust or 165°C, whichever is lower. b. 150°C under all conditions. c. No restrictions if dust is cleared regularly. d. Only based on ambient temperature. Incorrect. NEC requires stricter temperature controls in dusty environments. Correct! The lower value ensures safety. The temperature must not exceed the ignition temperature of the dust or 165°C, whichever is lower, considering the insulation effect of dust layers. Class II groups address dust types like metal, carbon, and others. 8 / 50 What are the three Class II dust groups (500.6(B))? a. E, F, G. b. None, as Class II does not have groups. c. A, B, C. d. G, H, J. Incorrect. The Class II groups are E, F, and G. Correct! Class II locations have these three dust groups. Class II groups are E (metal dusts), F (carbonaceous dusts), and G (other combustible dusts like flour and grain). Markings help ensure proper use and safety. 9 / 50 What marking is required for luminaires in Class II locations (502.130)? a. Voltage rating only. b. Type and maximum wattage of the lamp. c. No marking is required. d. Manufacturer's name and model number. Incorrect. Markings must include type and maximum wattage. Correct! Luminaires must be marked for type and maximum wattage. Luminaires must be marked with the type and maximum wattage of the lamp to ensure safe operation without exceeding temperature limits. Division 1 locations require robust containment methods. 10 / 50 What type of wiring is allowed in Class I, Division 1 locations (501.10(A))? a. Open wiring methods. b. Threaded rigid metal conduit (RMC) or intermediate metal conduit (IMC). c. Any non-metallic raceway. d. PVC conduit without restrictions. Incorrect. Division 1 requires more durable methods like RMC or IMC. Correct! Threaded RMC or IMC is required for these hazardous locations. Only robust methods like RMC or IMC are permitted due to the explosive potential of Division 1 locations. Noncombustible materials and ventilation mitigate hazards from fibers and lint. 11 / 50 What construction is required for storage battery charging equipment in Class III locations (503.160)? a. Rooms require explosionproof enclosures. b. No special construction is required. c. Equipment may be installed in general-purpose rooms. d. Rooms must be lined with noncombustible materials and well ventilated. Incorrect. Noncombustible construction and ventilation are mandatory. Correct! Noncombustible materials and ventilation are required for safety. Battery charging equipment must be located in rooms built or lined with noncombustible materials and constructed to prevent fiber intrusion, ensuring safety. Motors must prevent fiber accumulation and ignition. 12 / 50 How must motors and generators be constructed for Class III, Division 1 locations (503.125)? a. Any motor with thermal overload protection is permitted. b. Open-type motors are acceptable with guards. c. Only self-cleaning textile motors are allowed. d. Motors must be totally enclosed nonventilated, pipe ventilated, or fan cooled. Incorrect. Only totally enclosed designs are acceptable. Correct! Motors must be fully enclosed to prevent fiber ignition. Motors must be totally enclosed to prevent fiber buildup and ignition, ensuring safe operation in hazardous environments. Hazardous locations require secure and explosionproof terminations. 13 / 50 How should cables be terminated in Class I, Division 1 locations (501.15(A)(1))? a. With explosionproof cable glands listed for the location. b. Directly spliced with wire nuts. c. Using general-purpose connectors. d. Termination methods are optional. Incorrect. Only listed explosionproof cable glands are allowed. Correct! Terminations must use listed explosionproof glands. Cables must terminate using explosionproof glands that prevent the entry of hazardous gases or ignition risks. Flexible cords need special durability and dust-tight terminations. 14 / 50 What is required for flexible cords in Class III, Division 1 locations (503.140)? a. Cords can be general purpose if protected by guards. b. Any type of flexible cord is allowed. c. Cords must be listed for extra-hard usage and terminated with dust-tight connectors. d. Flexible cords must be sealed with tape. Incorrect. Flexible cords must meet strict standards for usage and termination. Correct! Extra-hard usage cords with dust-tight connectors are required. Flexible cords must be listed for extra-hard usage and terminate in dust-tight connectors to prevent fiber intrusion and ensure durability. Lighting must prevent fibers from entering and sparks from escaping. 15 / 50 What type of luminaires is permitted in Class III, Division 2 locations (503.130)? a. General-purpose luminaires. b. Open fixtures with protective guards. c. Luminaires designed to minimize the entrance of fibers and prevent spark escape. d. Only portable lighting systems. Incorrect. General-purpose luminaires are unsuitable for hazardous areas. Correct! Luminaires must prevent fiber entry and spark escape. Luminaires must be designed to minimize fiber entry and prevent sparks, ensuring safety in hazardous environments. Article 502 focuses on specific hazards involving combustible dust. 16 / 50 What does NEC Article 502 cover (502.1)? a. Electrical equipment and wiring in Class II, Division 1 and Division 2 hazardous locations. b. Only residential wiring in hazardous areas. c. General wiring methods for industrial locations. d. Electrical installations in Class I locations. Incorrect. Article 502 addresses Class II, Division 1 and Division 2 hazardous areas. Correct! Article 502 covers electrical installations in Class II locations. Article 502 applies to locations with combustible dust that poses fire or explosion risks. Division 1 locations require dust-tight or enclosed wiring systems. 17 / 50 What is required for wiring methods in Class III, Division 1 locations (503.10(A))? a. Wiring methods require explosionproof enclosures. b. Open wiring methods with guards are acceptable. c. Any general-purpose wiring method is allowed. d. Rigid metal conduit (RMC), PVC, or dust-tight wireways are required. Incorrect. Only specific dust-tight wiring methods are permitted. Correct! Division 1 locations require dust-tight or enclosed wiring systems. In Division 1, rigid conduits, dust-tight wireways, and similar enclosed methods ensure the containment of fibers and flyings, preventing ignition risks. Intrinsic safety minimizes ignition risk by limiting energy. 18 / 50 What type of protection is “intrinsic safety” (500.7(E))? a. Requires equipment to operate under high pressure. b. Only suitable for Division 1 locations. c. A method that prevents electrical faults entirely. d. Limits energy to a level incapable of causing ignition. Incorrect. Intrinsic safety limits energy to safe levels. Correct! Intrinsic safety limits energy to prevent ignition. Intrinsic safety ensures energy levels in circuits are too low to ignite flammable atmospheres, making it safe for hazardous locations. Dust-tight design is critical for safety in these locations. 19 / 50 What is required for boxes and fittings in Class II, Division 1 locations (502.10(A)(3))? a. No special requirements if they are indoors. b. They must be explosionproof. c. They must be dust-tight and use threaded connections. d. Fittings may use snap-on covers. Incorrect. Dust-tight and threaded connections are required. Correct! Dust-tight fittings with threaded connections are mandatory. Boxes and fittings must be dust-tight and use threaded bosses for secure, dust-tight conduit or cable terminations. Group B addresses highly explosive gases like hydrogen. 20 / 50 What defines the Group B classification in Class I locations (501.6(A))? a. Areas with high concentrations of dust. b. Locations with methane gas. c. Sites storing flammable liquids. d. Presence of hydrogen or gases with similar ignition properties. Incorrect. Group B is specific to hydrogen and similar gases. Correct! Group B involves hydrogen and similar ignition properties. Group B classifications apply to locations with hydrogen or gases with similar explosive properties, requiring special precautions. Division 2 allows dust-tight and ignition-proof designs. 21 / 50 What types of motors are permitted in Class II, Division 2 locations (502.125(B))? a. Motors with external cooling fans only. b. Only totally enclosed fan-cooled motors. c. Dust-ignitionproof motors or totally enclosed designs like nonventilated or pipe-ventilated. d. Open-type motors with no restrictions. Incorrect. Division 2 requires specific dust-tight or ignition-proof designs. Correct! Dust-ignitionproof or enclosed designs are required. Motors must be dust-ignitionproof or use designs that prevent dust accumulation, such as totally enclosed nonventilated or pipe-ventilated motors. Seals in Class II prevent dust, not gases. 22 / 50 How must conduit seals be handled in Class II locations (502.15)? a. Conduit seals are not required for Class II. b. Conduits must use explosionproof seals only. c. Only required for conduits over 10 feet. d. To prevent dust entry into dust-ignitionproof enclosures. Incorrect. Seals are required to prevent dust entry, not for explosionproof purposes Correct! Seals must prevent dust from entering enclosures. Conduit seals must prevent dust entry into dust-ignitionproof enclosures and are not required to be explosionproof. Proper seal placement minimizes explosion risks. 23 / 50 How must conduit seals be placed in Class I, Division 1 locations (501.15(A))? a. No sealing is required for small enclosures. b. Anywhere in the conduit run. c. Only at conduit terminations. d. Within 450 mm (18 inches) of an explosionproof enclosure. Incorrect. Seals must be placed within specified distances from enclosures. Correct! Seals are required within 450 mm of enclosures. Seals must be within 450 mm (18 inches) of enclosures to contain explosions and prevent gas migration. Cable seals prevent the spread of hazardous gases. 24 / 50 What are the sealing requirements for cables in Class I, Division 2 (501.15(E))? a. Cables may use open splices with approved tape. b. No sealing is required for Division 2. c. Sealing is only necessary for high-voltage cables. d. Cables must be sealed to prevent gas migration. Incorrect. Proper sealing is required for safety. Correct! Cables must be sealed to prevent gas migration. Cables in Division 2 locations must be sealed to prevent gas migration through the cable core, ensuring safety. Flexibility is necessary to minimize equipment vibration. 25 / 50 What is required for flexible connections in Class I, Division 1 locations (501.10(A)(2))? a. Any flexible conduit without fittings is allowed. b. Flexible conduits must be less than 1 meter in length. c. Flexible connections are prohibited. d. Listed flexible fittings or flexible cords terminated with listed connectors. Incorrect. Flexible connections must use listed components. Correct! Listed flexible fittings or cords are required. Flexible connections require listed fittings or cords to maintain safety while allowing movement or reducing vibrations. Even non-conductive cables can pose risks. 26 / 50 How must optical fiber cables in hazardous locations be sealed (500.8(F))? a. Using temporary insulation tape. b. Sealed to address both fire and explosion hazards. c. Sealing is not required for optical cables. d. Only with non-metallic fittings. Incorrect. Proper sealing is critical to address hazards. Correct! Sealing is essential to ensure safety. Optical fiber cables must be sealed to mitigate fire hazards and explosion risks, as specified by NEC requirements. This article addresses low-energy systems for hazardous environments. 27 / 50 What is the primary scope of NEC Article 504 (504.1)? a. General-purpose electrical installations. b. The installation of intrinsically safe apparatus and wiring in hazardous locations. c. High-voltage transmission lines. d. All fire-protective signaling systems. Incorrect. Article 504 is specific to intrinsically safe systems in hazardous areas. Correct! The article focuses on intrinsically safe systems in hazardous locations. Article 504 applies to intrinsically safe systems designed to limit energy levels to prevent ignition in hazardous (classified) locations. Grounding ensures safety and compliance in hazardous locations. 28 / 50 What grounding requirements apply in Class I locations (501.30(A))? a. Grounding is not required. b. Equipment grounding conductors are optional. c. Only high-voltage systems need grounding. d. Wiring systems and equipment must comply with Article 250. Incorrect. Grounding compliance with Article 250 is mandatory. Correct! Grounding must align with Article 250 requirements. Grounding and bonding must follow Article 250 to ensure safety and prevent faults. Dust ignition protection differs from explosionproof requirements. 29 / 50 What is the requirement for explosionproof equipment in Class II locations (502.5)? a. General-purpose equipment can be used with guards. b. Equipment must always be sealed with putty. c. Explosionproof equipment is not required unless identified for dust ignition prevention. d. Explosionproof equipment is always required. Incorrect. Equipment must be identified for dust ignition protection if required. Correct! Explosionproof equipment is not mandatory unless identified for dust ignition prevention. Equipment in Class II locations must prevent dust ignition and may not require explosionproof characteristics unless specifically identified. Thread engagement ensures safety against sparks. 30 / 50 What type of thread is required for equipment in Class I hazardous locations (500.8(E)(1))? a. Thread type is not specified. b. Loose threading to ensure easy disassembly. c. Metric threads only. d. NPT threads, with five threads fully engaged. Incorrect. NPT threads with proper engagement are required. Correct! Proper threading ensures enclosure safety. NPT threads with a minimum engagement of five threads are required to maintain explosionproof integrity in hazardous locations. This article focuses on environments where flammable gases and vapors are present. 31 / 50 What does NEC Article 501 cover (501.1)? a. Class II, Division 1 locations exclusively. b. Electrical equipment in Class I, Division 1 and Division 2 hazardous locations. c. General wiring methods for all industrial locations. d. Installations in unclassified areas only. Incorrect. Article 501 specifically addresses Class I locations. Correct! It governs Class I hazardous locations. Article 501 pertains to equipment and wiring in locations with flammable gases or vapors in quantities sufficient to create explosive mixtures. Class III focuses on fibers and flyings, not dust or gases. 32 / 50 What does NEC Article 503 cover (503.1)? a. Class III locations with nonmetal combustible fibers and ignitible flyings. b. General wiring methods for unclassified locations. c. Class II locations involving combustible dust. d. Only industrial locations with metal fibers. Incorrect. Class III is specific to fibers and flyings, not dust. Correct! Article 503 pertains to fibers and flyings. Article 503 addresses hazards related to nonmetal combustible fibers and ignitible flyings, such as in textile mills and woodworking plants. Division 1 signifies a high level of risk during normal operations. 33 / 50 How are Class I, Division 1 locations defined (501.1)? a. Areas only adjacent to hazardous equipment. b. Locations where flammable gases or vapors are present under normal operating conditions. c. Locations used for flammable material storage. d. Areas with occasional flammable gas leaks. Incorrect. Division 1 locations involve constant or predictable exposure to flammable gases. Correct! Division 1 signifies the higher-risk classification. Division 1 locations are those where ignitible gases or vapors exist during normal operations or are caused by frequent equipment faults. Markings must indicate compatibility with hazardous conditions. 34 / 50 What marking is required for equipment used in Class I, Division 2 locations (501.5)? a. Markings that identify suitability for Division 2 locations. b. Only voltage and current ratings are necessary. c. No markings are needed. d. Manufacturer’s logo only. Incorrect. Proper markings for Division 2 compatibility are mandatory. Correct! Equipment must be marked for Division 2 use. Equipment must be marked to show its suitability for Division 2 hazardous locations, ensuring proper use and compliance. Marking ensures the equipment’s surface temperature is safe for the location. 35 / 50 What is the temperature marking requirement for equipment in Class I locations (501.8(C))? a. Equipment must be marked with its maximum surface temperature. b. Marking is optional if installed indoors. c. Only for equipment over 500 volts. d. No marking is required if the temperature is below 100°C. Incorrect. Markings are required regardless of voltage or location. Correct! Equipment must display its maximum surface temperature. Equipment must have markings indicating the maximum surface temperature to ensure compatibility with hazardous atmospheres. Detailed markings ensure the fixture’s compatibility with the location. 36 / 50 What marking is required for lighting fixtures in Class I, Division 1 (501.130(A))? a. Class, Division, Group, and temperature ratings. b. Voltage and wattage only. c. Only the manufacturer’s name and model number. d. Marking is optional for small fixtures. Incorrect. Complete markings are necessary for hazardous environments. Correct! Markings include Class, Division, Group, and temperature ratings. Lighting fixtures must be marked with the Class, Division, Group, and temperature ratings to confirm suitability for the hazardous location. Division 1 requires robust, dust-tight wiring methods. 37 / 50 What wiring methods are permitted in Class II, Division 1 locations (502.10(A))? a. Any wiring system approved for unclassified locations. b. PVC conduit without restrictions. c. Threaded RMC or IMC, Type MI cable, and listed flexible connections. d. Open wiring methods only. Incorrect. Division 1 requires specific methods like RMC or IMC. Correct! Only robust and listed wiring methods are permitted in Division 1. Only threaded rigid metal conduit (RMC), intermediate metal conduit (IMC), or listed methods like Type MI cable are permitted to ensure containment and dust-tight connections. Division 2 allows broader wiring methods than Division 1, with conditions. 38 / 50 What wiring methods are acceptable in Class I, Division 2 locations (501.10(B))? a. Non-metallic raceways without any restrictions. b. Only RMC or IMC conduits. c. Wiring methods permitted for unclassified locations if they prevent the escape of gases. d. Open wiring is allowed for short runs. Incorrect. Only methods that prevent gas escape are permitted. Correct! Wiring methods must prevent gas migration. Wiring methods for unclassified locations are acceptable in Division 2 if they are sealed or designed to prevent gas migration, ensuring compliance and safety. T4 indicates a specific temperature class for hazardous locations. 39 / 50 What is the maximum surface temperature for T4-rated equipment (501.8(C))? a. 450°C (842°F). b. No specific temperature limit applies. c. 135°C (275°F). d. 85°C (185°F). Incorrect. T4 ratings are limited to 135°C. Correct! The maximum surface temperature is 135°C. T4-rated equipment must not exceed 135°C to prevent ignition in hazardous atmospheres. Sealing protects against dust entering enclosures through raceways. 40 / 50 What is the minimum sealing length for a vertical raceway extending from a dust-ignitionproof enclosure (502.15)? a. 10 meters (33 feet). b. 12 inches. c. Sealing is not required for vertical raceways. d. 1.5 meters (5 feet). Incorrect. The minimum sealing length for vertical raceways is 1.5 meters. Correct! Vertical raceways must extend downward 1.5 meters to meet NEC requirements. Vertical raceways must extend at least 1.5 meters (5 feet) downward from dustignitionproof enclosures to prevent dust entry. Sealing protects against dust entering enclosures through raceways. 41 / 50 What is the minimum sealing length for a vertical raceway extending from a dust-ignitionproof enclosure (502.15)? a. 1.5 meters (5 feet). b. 12 inches. c. 10 meters (33 feet). d. Sealing is not required for vertical raceways. Incorrect. The minimum sealing length for vertical raceways is 1.5 meters. Correct! Vertical raceways must extend downward 1.5 meters to meet NEC requirements. Vertical raceways must extend at least 1.5 meters (5 feet) downward from dustignitionproof enclosures to prevent dust entry. Flexible cords require special termination in hazardous areas. 42 / 50 How should flexible cords be terminated in Class II, Division 1 locations (502.140(B))? a. Using wire nuts for dust-tight connections. b. With cord connectors listed for the location or installed with a seal. c. Flexible cords are not permitted in Division 1. d. With general-purpose connectors. Incorrect. Flexible cords need specific listed connectors or seals. Correct! Listed connectors or seals are mandatory for flexible cords. Flexible cords in Division 1 must use listed cord connectors or seals to maintain dusttight and ignition-proof integrity. Lighting must be designed for hazardous dust conditions. 43 / 50 What type of luminaires is required in Class II, Division 1 (502.130(A))? a. Portable lights with open designs. b. Luminaires identified for Class II locations. c. Standard residential fixtures. d. Only fluorescent lights with covers. Incorrect. Only identified luminaires are suitable for Division 1. Correct! Luminaires must be identified for Class II locations. Luminaires in Class II, Division 1 must be specifically identified for such use and capable of preventing dust ignition. Hazardous locations require specially designed luminaires. 44 / 50 What is required for luminaires in Class I, Division 1 (501.130(A))? a. General-purpose luminaires with LED bulbs. b. Luminaires identified for the specific hazardous location. c. Open fixtures with protective cages. d. Fluorescent lights only. Incorrect. General-purpose luminaires are not suitable for hazardous locations. Correct! Luminaires must be specifically identified for Class I, Division 1. Luminaires must be identified for Class I, Division 1, and capable of operating safely in explosive environments. Conduit seals are designed for containment and prevention. 45 / 50 What is the purpose of conduit seals in Class I locations (501.15)? a. To separate power and control circuits. b. To prevent the migration of gases and flames. c. To physically support wiring in long runs. d. To allow for expansion and contraction of conduits. Incorrect. Seals are for containing gases and flames, not mechanical purposes. Correct! Seals prevent gas migration and flame propagation. Seals in conduits are used to prevent hazardous gases from migrating through the conduit and to contain potential explosions within enclosures. PVC conduits require additional safeguards in hazardous areas. 46 / 50 What additional protection is required for PVC conduit in Class I, Division 1 (501.10(A))? a. No protection needed. b. Encasement in a concrete envelope and specific burial depths. c. Grounding with non-metallic straps. d. Threadless fittings. Incorrect. PVC must be encased and buried appropriately. Correct! Concrete encasement and burial depths are required. PVC must be encased in concrete and buried with specific cover depths to prevent exposure to hazardous gases. Division 1 involves continuous or frequent exposure to dust. 47 / 50 How are Class II, Division 1 locations defined (502.1, 500.5(C))? a. Locations with ignitable gases. b. Locations where combustible dust is present under normal operating conditions or due to maintenance or leaks. c. Areas with occasional dust presence. d. Areas adjacent to Class III hazardous locations. Incorrect. Division 1 deals with frequent or continuous dust presence. Correct! Division 1 locations involve continuous or frequent exposure to combustible dust. Class II, Division 1 locations involve hazardous dust present during normal operations or due to equipment maintenance or leaks. Unmarked equipment has default temperature limits. 48 / 50 What are the allowable ambient temperature ranges for equipment without special marking (500.8(C)(5))? a. Above 40°C only. b. 0°C to +50°C. c. No temperature restrictions apply. d. -25°C to +40°C. Incorrect. The standard range is -25°C to +40°C. Correct! Equipment without marking must operate within this range. Equipment without special ambient temperature marking is suitable for operation in the range of -25°C to +40°C. Grounding protects against static electricity and faults. 49 / 50 What grounding requirements apply to enclosures in Class I, Division 2 (501.30(B))? a. Only grounded for equipment operating above 250 volts. b. All metallic enclosures must be bonded and grounded per Article 250. c. No grounding is required for explosionproof enclosures. d. Grounding is optional if equipment is indoors. Incorrect. Grounding is mandatory for all metallic enclosures. Correct! Article 250 requires grounding of metallic enclosures. Metallic enclosures must be bonded and grounded to prevent sparks and ensure safety in hazardous environments. Division 2 enclosures must prevent dust entry. 50 / 50 What is the minimum requirement for enclosures in Class II, Division 2 locations (502.115(B))? a. Only metallic enclosures are permitted. b. Enclosures must be explosionproof. c. Enclosures require no special identification. d. They must be dust-tight or otherwise identified for the location. Incorrect. Dust-tight or identified enclosures are mandatory. Correct! Enclosures must meet dust-tight or hazard-specific requirements. Enclosures in Division 2 must be dust-tight or identified for the specific hazards present, ensuring safety and compliance. Your score is LinkedIn Facebook Twitter 0% Restart quiz Exit Rate & Review Thank you for taking the time to leave us a review! Your feedback is greatly appreciated and helps us improve our services. Send feedback Leave a Reply Cancel replyYour email address will not be published. Required fields are marked * Comment* Name* Email* Website Save my name, email, and website in this browser for the next time I comment. Post Comment