What you’ll learn
After this post, you will be able to build a voltmeter from a meter movement and a multiplier resistor, work out the multiplier you need, and check how much your meter is dragging the voltage down — the loading effect — with one simple accuracy ratio.
A voltmeter is a movement plus a big resistor
Voltmeters are used extensively wherever the surveillance of input and output voltages is vital to plant operation. A simple DC voltmeter is a resistor called a multiplier, R_S, in series with the meter movement, with the meter face marked to read voltage. It is connected in parallel with the load R_L being measured — across it, never through it.
The multiplier does the heavy lifting. The movement itself can only carry a tiny current (usually under 1 mA), so the multiplier drops most of the voltage and lets only the movement’s small current through. Sizing it is Eq. (14-1): V = I_m·R_S + I_m·R_m, so R_S = V/I_m − R_m, where V is the voltage range you want, I_m is the meter current, R_m is the meter’s internal resistance, and R_S is the multiplier. The handbook notes R_m is usually negligibly small compared with R_S, so in practice R_S ≈ V/I_m.
The worked example: sizing a multiplier
Take a 2 mA movement with 25 Ω internal resistance, and make a voltmeter with a 100 V full-scale range. R_S = V/I_m − R_m = 100/(2×10⁻³) − 25 = 50,000 − 25 = 49,975 Ω — essentially 50 kΩ, since the 25 Ω is negligible beside it. That is the whole construction: a 50 kΩ resistor in series with a 2 mA movement, and a face marked 0–100 V.
The loading effect: your meter steals current
Here is the catch. A connected voltmeter draws current, and that current causes a voltage drop across the meter’s own resistance that is subtracted from the voltage being measured. The meter disturbs the very circuit it is measuring. In a low-current circuit this can seriously affect accuracy — the meter is no longer a silent observer.
How bad is it? The handbook’s accuracy ratio, K_V, is the voltage measured with the meter in circuit (V_W) divided by the true voltage with the meter out of circuit (V_O): K_V = V_W/V_O. It can also be written from resistances: K_V = R_in/(R_O + R_in), where R_O is the circuit resistance and R_in is the voltmeter’s input resistance. A meter’s input resistance comes from its sensitivity: sensitivity (Ω/V) × range = input resistance. High input resistance — high Ω/V sensitivity — is what keeps the loading error small, and it is the practical reason to choose a high-sensitivity meter for low-current circuits.
The worked example: 99% — and a handbook slip to flag
A 100 V-range voltmeter with a sensitivity of 40 kΩ/V measures the voltage across the terminals a–b of a circuit with two 100 kΩ resistors across a 220 V source. First the true voltage: V_O = (100 kΩ/(100 kΩ + 100 kΩ)) × 220 V = 110 V. Then the meter’s input resistance: R_in = sensitivity × range = 40 kΩ/V × 100 V. The handbook prints this as 4.4 MΩ — but 40 kΩ/V × 100 V is 4 MΩ arithmetically, so the printed 4.4 MΩ is a slip in the handbook. The handbook’s own worked result follows the printed value, so we keep both: with R_in = 4.4 MΩ and R_O = (100×100)/(100+100) = 50 kΩ, V_W = [R_in/(R_O + R_in)] × V_O = 0.99 × 110 = 108.9 V, and K_V = 108.9/110 = 0.99, or 99%. The meter reads 108.9 V where the true voltage is 110 V — a 1% lie, small here only because the meter’s input resistance is far larger than the circuit’s 50 kΩ.
Common mistakes
- “A voltmeter reads the true voltage.” It reads the voltage with itself connected, and its own current draw drags that voltage down. In low-current circuits the error is serious, not trivial.
- “Connect the voltmeter in series, like an ammeter.” Never — a voltmeter goes in parallel with the load. A series-connected voltmeter, with its high resistance, would not measure the load voltage and would disturb the circuit.
- “Any voltmeter is fine for any circuit.” The meter’s input resistance decides the error. A low-sensitivity meter on a high-resistance circuit can be badly wrong; high Ω/V sensitivity is what you want for low-current circuits.
- “The multiplier is a minor detail.” The multiplier is the voltmeter: it drops almost all the voltage and sets the range. Get it wrong and the range is wrong.
- “Accuracy is only about calibration.” The loading effect is an accuracy error too — it comes from the meter disturbing the circuit, and no amount of calibration removes it.
- “The handbook’s numbers always check out.” In this chapter’s example the printed input resistance, 4.4 MΩ, does not match its own arithmetic, 40 kΩ/V × 100 V = 4 MΩ. The 99% result follows the printed value. Check the arithmetic, even in the handbook.
Summary
A voltmeter is a meter movement plus a series multiplier, connected in parallel with the load, with R_S = V/I_m − R_m setting the range. But the moment you connect it, it draws current and drags the voltage down — the loading effect. The accuracy ratio K_V = V_W/V_O = R_in/(R_O + R_in) tells you how much: in the handbook’s example, 108.9 V measured against 110 V true, 99% accurate, because the meter’s input resistance dwarfed the circuit’s. Choose a high-sensitivity meter, connect it in parallel, and always ask how much your meter is lying.
Quick-check questions
- What is a voltmeter made of, and how is it connected?
- How do you size the multiplier resistor?
- What is the loading effect?
- What is the accuracy ratio K_V, and what two ways can you write it?
- In the handbook’s example, what did the meter read, what was the true voltage, and how accurate was it?
Answers: 1. A resistor called a multiplier (R_S) in series with the meter movement, with the face marked to read voltage; connected in parallel with the load being measured. 2. R_S = V/I_m − R_m, where V is the desired range, I_m the meter current, R_m the meter resistance. R_m is usually negligible, so R_S ≈ V/I_m — 50 kΩ for a 2 mA movement on a 100 V range. 3. The connected voltmeter draws current, causing a voltage drop across the meter’s resistance that is subtracted from the voltage being measured — the meter disturbs the circuit it measures. 4. K_V = V_W/V_O, the voltage with the meter in circuit divided by the true voltage; also K_V = R_in/(R_O + R_in). 5. The meter read 108.9 V against a true voltage of 110 V — K_V = 0.99, or 99% accurate. (Note: the handbook prints R_in as 4.4 MΩ, though 40 kΩ/V × 100 V = 4 MΩ; the 99% result follows the printed value.)
Based on DOE-HDBK-1011/92, Electrical Science, Module 14, paraphrased for study.
Top 10 Scorers
| Pos. | Name | Score | Duration |
|---|---|---|---|
| There is no data yet |
What is a simple DC voltmeter made of?
A resistor called a multiplier in series with the meter movement, with the meter face marked to read voltage
Question Explanation:
A simple DC voltmeter is a resistor R_S called a multiplier in series with the meter movement, with the meter face marked to read voltage.
How is a voltmeter connected to the load being measured?
In parallel with the load
Question Explanation:
A voltmeter is connected in parallel with the load R_L being measured — across it, never through it.
What formula gives the multiplier resistance R_S for a voltmeter?
R_S = V / I_m − R_m
Question Explanation:
Eq. (14-1): V = I_m·R_S + I_m·R_m, so R_S = V/I_m − R_m. R_m is usually negligibly low compared with R_S, so in practice R_S ≈ V/I_m.
A 2 mA meter movement with an internal resistance of 25 Ω is to be used as a 100 V voltmeter. What is the multiplier resistance R_S?
About 50 kΩ
Question Explanation:
R_S = 100/(2×10⁻³) − 25 = 50,000 − 25 = 49,975 Ω — essentially 50 kΩ, since the 25 Ω is negligible beside it.
What is the loading effect?
The error caused when the current drawn by a voltmeter changes the voltage it is trying to measure
Question Explanation:
When a voltmeter is connected in parallel with a resistor, current flows through the meter too. That changes the voltage drop across the resistor — the loading effect. It can seriously affect accuracy, especially in low-current circuits.
What is the accuracy ratio K_V?
K_V = V_W / V_O, the voltage with the meter in circuit over the true voltage
Question Explanation:
K_V is the ratio of the voltage measured with the meter in circuit (V_W) to the voltage with the meter out of circuit, the true voltage (V_O): K_V = V_W/V_O.
How else can K_V be written, using resistances?
K_V = R_in / (R_O + R_in)
Question Explanation:
K_V can also be written as R_in/(R_O + R_in), where R_O is the circuit resistance and R_in is the input resistance of the voltmeter.
How do you find a voltmeter's input resistance from its sensitivity?
Multiply the sensitivity in ohms per volt by the range
Question Explanation:
A voltmeter's input resistance is its sensitivity in ohms per volt multiplied by its range: R_in = S_V × range.
In the handbook's worked example, the true voltage is 110 V and the meter reads 108.9 V. What is the accuracy ratio K_V?
0.99
Question Explanation:
The true voltage V_O = (100/(100+100)) × 220 = 110 V. With R_O = 50 kΩ and the handbook's printed R_in = 4.4 MΩ, V_W = 0.99 × 110 = 108.9 V, and K_V = 108.9/110 = 0.99, or 99%.
In the handbook's worked example, the printed input resistance is 4.4 MΩ. What is wrong with that value?
40 kΩ/V × 100 V = 4 MΩ, not 4.4 MΩ — the printed value is a slip, though the 99% result follows the printed value
Question Explanation:
40 kΩ/V × 100 V is 4 MΩ arithmetically, not the 4.4 MΩ printed in the handbook. The handbook's worked result of 108.9 V and 99% follows from the printed 4.4 MΩ value, so both the printed value and the discrepancy are recorded — no correction substituted.