Article 100-110 Quiz01

This quiz includes 20 questions selected from NEC Articles 100 to 110. The questions are chosen randomly, with no repeats from other quizzes—unless a particular question is used again on purpose because it relates to more than one topic, such as both cable ampacity and cable application.

If you spot any issues or have suggestions, you’re welcome to report questions or review the quiz. Your feedback matters, and contributions to help improve and refine the questions and quizzes are always appreciated.

Connections depend on the lowest-rated component.

1 / 20

What are the temperature limitations for conductor connections in
Article 110.14?

The fault current is a critical factor.

2 / 20

How does Article 110.9 address interrupting ratings?

Wiring must function as intended without faults.

3 / 20

How does Article 110.7 ensure wiring integrity?

The article sets broad standards for electrical installations.

4 / 20

What is covered under Article 110?

Lockability must persist, even without the lock present.

5 / 20

What does Article 110.25 require for lockable disconnecting means?

Accessibility for maintenance is critical.

6 / 20

How does Article 110.26 define the required working space around
electrical equipment?

Approval is determined by an overseeing authority

7 / 20

What does "Approved" equipment mean in the context of NEC Article
110?

Proper use depends on clear guidance.

8 / 20

What must equipment listings include according to Article 110.3(B)?

The NEC allows multiple conductor materials.

9 / 20

What materials are generally permitted for electrical conductors?

Safety and protection are key purposes.

10 / 20

What is an "Enclosure"?

Identification ensures safety in multi-phase systems.

11 / 20

What does Article 110.15 require for high-leg conductors in a 4-wire
delta system?

Identification helps avoid confusion during operation.

12 / 20

What does Article 110.22 require for disconnecting means
identification?

Environment-specific identification is essential.

13 / 20

What does Article 110.11 specify regarding deteriorating agents?

Grounding ensures electrical stability and safety

14 / 20

What does "Grounded" mean?

It pertains to dust ingress under certain conditions.

15 / 20

What does "Dusttight" mean?

It compares demand to load capacity.

16 / 20

What is a "Demand Factor"?

Markings must be clear and long-lasting.

17 / 20

What does Article 110.21(B) specify about field-applied hazard
markings?

They are not required for temporary installations.

18 / 20

What is required for enclosures in damp or wet locations under Article
110.28?

Fault current impacts interrupting capability.

19 / 20

What is the purpose of field marking available fault current under
Article 110.24?

ESS involves storing and supplying energy.

20 / 20

How is "Energy Storage System (ESS)" defined?

Your score is

0%

Exit

Rate & Review

Thank you for taking the time to leave us a review! Your feedback is greatly appreciated and helps us improve our services.

Pos.NameScoreDuration
1jalva292100 %12 minutes 12 seconds
2ericyd95 %3 minutes 3 seconds
3Guest95 %4 minutes 15 seconds
4Guest95 %8 minutes 42 seconds
5Guest85 %13 minutes 7 seconds
6jalva29285 %20 minutes 1 seconds
7Guest80 %5 minutes 2 seconds
8Guest80 %6 minutes 3 seconds
9Guest75 %3 minutes 35 seconds
10Guest70 %6 minutes 8 seconds

Leave a Reply

Your email address will not be published. Required fields are marked *