Article 100-110 Quiz06

This quiz includes 20 questions selected from NEC Articles 100 to 110. The questions are chosen randomly, with no repeats from other quizzes—unless a particular question is used again on purpose because it relates to more than one topic, such as both cable ampacity and cable application.

If you spot any issues or have suggestions, you’re welcome to report questions or review the quiz. Your feedback matters, and contributions to help improve and refine the questions and quizzes are always appreciated.

Consider if an interrupting rating sets a minimum or maximum standard for performance.

1 / 14

An interrupting rating is a minimum rating, which is a measure of the fuse’s or circuit breaker’s ability to safely open an electrical circuit under fault conditions, such as a short circuit, or ground fault.

2 / 14

Feeders are the part of the electrical system that connects the branch-circuit ____ to the electrical service equipment.

3 / 14

Unless marked otherwise, the temperature rating of the terminal(s) for the following conductors or overcurrent device is:

4 / 14

Where would you find the definition for the term “readily accessible”?

5 / 14

Record the first 4 words of NEC 2020/ 110.3(B)

{blank_1}

6 / 14

The interior of enclosures or raceways installed underground shall be considered to be a wet location

Think about the behavior of fault currents compared to normal operation.

7 / 14

Short-circuit and ground-fault currents have the following characteristics:
They flow outside the normal current path.
They may be greater than the normal current.
They may be less than the normal current.

8 / 14

The NEC defines a(n) ____ as one familiar with the construction and operation of the equipment and the hazards involved.

9 / 14

Our job is to install the electrical system so proper voltage is supplied at the line terminals of the equipment.

10 / 14

An ungrounded conductor is also known as a ____ conductor.

The NEC definitions section is where you’ll find fundamental terms and definitions.

11 / 14

Where can you find the definitions for Luminaires and Lighting Outlets?
Options:

12 / 14

Most electrical equipment termination rating is at 60 or 75 degree Celsius.

The professional responsible for designing and specifying electrical systems typically makes these decisions.

13 / 14

In just about all applications, the type and sizing of the generator equipment is left to the ___________.

Consider whether a circuit breaker can be used if the equipment is only marked with a fuse size.

14 / 14

If equipment is marked with a maximum fuse size only and not an overcurrent device, you should avoid using a circuit breaker.