eep April 7, 2025 NEC 200-285 NEC Quizzes Report a question What’s wrong with this question? You cannot submit an empty report. Please add some details. 0% Article 200-285 Part08 This comprehensive quiz contains 50 questions carefully selected from the National Electrical Code (NEC) Articles spanning 200 through 285. These articles cover a broad spectrum of vital topics related to electrical installations within this section of the code. The questions in this quiz are chosen randomly to provide a thorough assessment of your knowledge across these essential NEC articles. While we strive for a diverse set of questions, some fundamental principles may be revisited in different contexts due to their relevance to multiple sections within this range. This approach ensures a robust evaluation of your understanding. We encourage you to actively participate and provide feedback. If you identify any issues or have suggestions for improving the quiz questions, please report them. Your contributions are invaluable in helping us maintain the accuracy and effectiveness of these learning resources. Think about the common maximum ampacity allowed for 12 AWG copper conductors. 1 / 50 The maximum overcurrent protection for 12 AWG copper conductors is _______ amperes. a. 20 b. 30 c. 15 d. 25 Incorrect. The maximum overcurrent protection for 12 AWG copper conductors is 20 amperes, as outlined in NEC Article 240.4(D)(5). Correct! NEC Article 240.4(D)(5) specifies that the maximum overcurrent protection for 12 AWG copper conductors is 20 amperes. According to NEC Article 240.4(D)(5), 12 AWG copper conductors are limited to a maximum overcurrent protection of 20 amperes. This rating ensures that the conductor is protected from excessive heat and current, which could result in damage or fire hazards. Look for the article that covers grounding and bonding in detail, ensuring electrical systems are safe and stable. 2 / 50 The NEC covers grounding and bonding in several articles, but the primary coverage is in Article ____. a. 215 b. 100 c. 230 d. 250 “Incorrect. While other articles reference grounding and bonding, NEC Article 250 is the primary article that comprehensively covers these topics.” “Correct! NEC Article 250 provides the primary coverage for grounding and bonding in electrical systems.” NEC Article 250 is the key article that covers the requirements for grounding and bonding electrical systems. Grounding provides a reference point for electrical systems and helps protect against electrical shock, while bonding ensures all conductive parts are connected to maintain electrical continuity and safety. Although other articles mention grounding and bonding, Article 250 is the main source for detailed requirements. Consider if overcurrent devices can be used in specific applications like motor overload protection. 3 / 50 Overcurrent devices are permitted to be used in ground conductors when used for motor overload protection. a. True b. False Incorrect. Overcurrent devices can be used for motor overload protection in ground conductors. Correct! Overcurrent devices are allowed for this specific application. NEC 240.22(2) permits overcurrent devices to be used in ground conductors specifically for motor overload protection, ensuring the safe operation of motors under overload conditions. Consider the standard percentage used to ensure safety for continuous loads that operate for long periods, as outlined by the NEC. 4 / 50 Unless the overcurrent device and its enclosure, such as a panelboard, is rated for operation at 100% of its rating, continuous loads (operating for three hours or more) are limited to no more than __% of the rating. a. 75 b. 80 c. 90 d. 100 Incorrect. For continuous loads operating for three hours or more, the NEC limits the load to 80% of the overcurrent device’s rating unless the device is rated for 100% operation, as per NEC Articles 210.19(A)(1) and 215.2(A)(1). Correct! Continuous loads are limited to 80% of the overcurrent device’s rating unless the device and enclosure are rated for 100% operation, according to NEC Articles 210.19(A)(1) and 215.2(A)(1). For continuous loads operating for three hours or more, NEC Articles 210.19(A)(1) and 215.2(A)(1) require that the load must not exceed 80% of the overcurrent device’s rating unless the device and its enclosure are rated for 100% operation. This is to prevent overheating and ensure the long-term safety of the electrical system. Consider the fact that short-circuit and ground-fault currents can deviate significantly from the normal operating current and may not always exceed it. 5 / 50 Short-circuit and ground-fault currents have the following characteristics: They flow outside the normal current path. They may be greater than the normal current. They may be less than the normal current. a. True b. False Incorrect. Short-circuit and ground-fault currents may flow outside the normal current path and can vary in magnitude—sometimes they are greater, and sometimes they are less than the normal operating current, as explained in NEC Article 250.2. Correct! Short-circuit and ground-fault currents can flow outside the normal current path and may be greater or less than the normal current, as outlined in NEC Article 250.2. Short-circuit and ground-fault currents do not follow the normal current path and can have a wide range of magnitudes. They can be greater than normal due to the low impedance of the fault, or in certain conditions, less than the normal current, depending on factors like fault location and the system’s protective devices. This is covered under NEC Article 250.2. Think about why grounding is important for stability and safety in transformer secondary circuits. 6 / 50 Is it required to ground the center tap of a single-phase transformer’s secondary? a. No b. Yes “Incorrect. The center tap of a single-phase transformer’s secondary is required to be grounded, according to NEC 250.30(A), to provide stability and safety in the electrical system.” “Correct! NEC 250.30(A) specifies that the center tap of a single-phase transformer’s secondary must be grounded for safety and system stability.” For single-phase transformers, the center tap of the transformer’s secondary winding is typically grounded, as required by NEC 250.30(A). Grounding the center tap creates a neutral point that stabilizes the system and ensures protection from electrical faults. This helps to prevent dangerous voltage imbalances and provides a path for fault currents, ensuring the safety of the system and anyone working around it. Consider the safety and accessibility requirements for building occupants in case they need to reset or disconnect their circuits. 7 / 50 As long as a qualified electrician has access to the overcurrent devices for the branch circuit, it does not matter if the commercial building’s tenant has access to them. a. False b. True Incorrect. Tenants in commercial buildings must have access to overcurrent devices for their branch circuits, as required by NEC Article 240.24(B). It is not sufficient for only a qualified electrician to have access. Correct! NEC Article 240.24(B) mandates that tenants in commercial buildings must have access to the overcurrent devices for their branch circuits. According to NEC Article 240.24(B), it is essential that the occupants (or tenants) of a commercial building have access to the overcurrent protection devices for their branch circuits. This allows them to reset or disconnect circuits as necessary, ensuring safety in case of emergencies or maintenance needs. Consider the article that focuses on protecting conductors and circuits from excessive current using devices like circuit breakers and fuses. 8 / 50 NEC Article ___ sets forth the requirements for overcurrent protection of conductors and for overcurrent devices. a. 210 b. 200 c. 220 d. 240 Incorrect. NEC Article 240 specifies the requirements for overcurrent protection of conductors and the use of overcurrent devices such as fuses and circuit breakers to protect against excess current. Correct! NEC Article 240 sets forth the requirements for overcurrent protection of conductors and the use of overcurrent protection devices. NEC Article 240 addresses the protection of electrical conductors and circuits by requiring the use of overcurrent protection devices such as fuses and circuit breakers. These devices are critical for preventing damage caused by excess current, ensuring the safe operation of electrical systems. Consider the ampacity limits for 12 AWG copper conductors. 9 / 50 The maximum overcurrent protection of 12 AWG Copper conductors is: a. 15 b. 25 c. 20 d. 30 Incorrect. This value exceeds the NEC limit for 12 AWG copper conductors. Correct! 20 amperes is the maximum overcurrent protection for 12 AWG copper conductors. NEC 240.4(D) specifies that the maximum overcurrent protection for 12 AWG copper conductors is 20 amperes to prevent overheating and ensure safe operation. Think about the NEC requirement that involves grounding conductive materials that enclose electrical equipment to protect against electrical faults. 10 / 50 Which term refers to normally non-current-carrying conductive materials enclosing electrical conductors or equipment, which must be connected to earth to limit the voltage to ground? a. Grounding Electrode b. Grounding Electrode Conductor c. Grounding, Electrical System d. Grounding of Electrical Equipment “Incorrect. The correct term is ‘Grounding of Electrical Equipment,’ which refers to connecting non-current-carrying conductive materials to earth to limit voltage and enhance safety.” “Correct! ‘Grounding of Electrical Equipment’ involves connecting non-current-carrying conductive materials to earth, as required by NEC, to limit the voltage and ensure safety.” The correct answer, Grounding of Electrical Equipment, refers to the practice of connecting non-current-carrying conductive materials, such as enclosures and frames, to the earth. This ensures that if a fault occurs, the conductive materials will be at or near ground potential, helping to prevent electric shock or fire by providing a path for fault current to safely dissipate. Think about commonly used fuse sizes in residential and small commercial electrical systems. 11 / 50 A standard fused disconnect has an ampere rating of 30 amperes. a. True b. False Incorrect. 30 amperes is a standard ampere rating for fused disconnects, as specified in NEC Article 240.6(A). Correct! 30 amperes is a standard ampere rating for fused disconnects, as outlined in NEC Article 240.6(A). According to NEC Article 240.6(A), 30 amperes is one of the standard ampere ratings for fused disconnects. This size is commonly used for smaller electrical systems, including residential circuits and some commercial applications. Think about which conductor is required to be grounded to ensure a stable electrical system and protection against electrical faults in service-entrance equipment. 12 / 50 According to NEC 250.26, the identified neutral conductor is the conductor required to be grounded when grounding service-entrance equipment. Is this statement true or false? a. False b. True “Incorrect. NEC 250.26 states that the identified neutral conductor is the conductor required to be grounded in service-entrance equipment to ensure system stability and safety.” “Correct! According to NEC 250.26, the identified neutral conductor is the conductor that must be grounded in service-entrance equipment.” NEC 250.26 requires that the identified neutral conductor (grounded conductor) be grounded in the service-entrance equipment. Grounding this conductor creates a stable reference point for the electrical system and provides a path for fault current, ensuring safety from electrical shock and equipment damage. Consider the NEC’s definition of continuous loads, which relates to loads that are expected to run for an extended period. 13 / 50 A circuit breaker is not permitted to be loaded to more than 80% of its current rating for loads that are likely to be on for __ hours or more. a. 3 b. 1 c. 4 d. 2 Incorrect. Circuit breakers must not be loaded to more than 80% of their rating for loads that operate for 3 hours or more, as specified in NEC Article 210.19(A)(1). Correct! A circuit breaker is not permitted to be loaded to more than 80% of its current rating for loads that are on for 3 hours or more, according to NEC Article 210.19(A)(1). According to NEC Article 210.19(A)(1), for loads that are expected to be on for 3 hours or more, the circuit breaker cannot be loaded to more than 80% of its rated current unless it is specifically rated for 100% continuous operation. This rule is to prevent overheating and ensure safe operation of electrical circuits under continuous load conditions. Consider the NEC’s requirement for maintaining a low-impedance path to safely carry fault current and prevent it from flowing on unintended metal objects. 14 / 50 Is it true that some of the fault current might flow on sheet metal ductwork, metal water, or metal gas piping, which is why the NEC emphasizes keeping the impedance of the ground-fault current path as low as possible? a. False b. True Incorrect. NEC 250.4(A)(5) emphasizes that the ground-fault current path must have low impedance to prevent fault current from flowing on unintended metal objects like sheet metal ductwork or metal piping. Correct! NEC 250.4(A)(5) requires a low-impedance ground-fault current path to prevent fault current from flowing on unintended metal objects like sheet metal ductwork and metal piping. According to NEC 250.4(A)(5), the NEC requires the ground-fault current path to have low impedance to ensure that fault current flows safely back to the grounding system. If not properly grounded, fault current might flow on unintended metal objects like sheet metal ductwork, water, or gas piping, creating dangerous conditions. Proper bonding helps mitigate this risk. Consider the NEC section that addresses bonding requirements for metal gas piping to ensure safety. 15 / 50 The bonding of metal gas piping is required by which NEC section? a. 250.86(A) b. 250.104(B) c. 250.122 d. 250.66 “Incorrect. The bonding of metal gas piping is specifically required by NEC 250.104(B) to ensure safety in case of electrical faults.” “Correct! NEC 250.104(B) requires the bonding of metal gas piping to ensure electrical safety and prevent shock hazards.” NEC 250.104(B) specifies that metal gas piping must be bonded to the electrical system’s grounding electrode system. This bonding ensures that the metal gas piping does not become energized and pose a shock hazard in the event of a fault, thereby maintaining electrical safety. Consider the standard interrupting rating for circuit breakers. 16 / 50 Every breaker having an interrupting rating other than _____ is to have its interrupting rating shown on the breaker. a. 5000 b. 9000 c. 7500 d. 2500 Incorrect. This value is not the standard rating for circuit breakers. Correct! 5000 amperes is the standard interrupting rating. NEC 240.83(C) requires that circuit breakers with an interrupting rating other than 5000 amperes must have their interrupting rating clearly marked on the breaker for safety and compliance purposes. Consider the areas where placing overcurrent devices could create safety hazards, such as potential fire risks or limited access during emergencies. 17 / 50 Additional major concerns regarding the location of overcurrent devices include that they are not permitted to: a. Be installed in clothes closets. b. Be installed in bathrooms. c. Be installed over the steps of a stairway. d. Be exposed to physical damage e. Be installed in the vicinity of easily ignitable material. Incorrect. Overcurrent devices are not allowed to be exposed to physical damage, placed near easily ignitable materials, installed in clothes closets or bathrooms, or located over the steps of a stairway, as per NEC Article 240.24. Correct! NEC Article 240.24 outlines that overcurrent devices must not be exposed to physical damage, installed near easily ignitable materials, placed in clothes closets or bathrooms, or installed over stairway steps. The NEC imposes strict requirements for the placement of overcurrent devices to ensure safety. NEC Article 240.24 prohibits installing overcurrent devices in areas where they could be damaged, near easily ignitable materials, in clothes closets, bathrooms, or over stairways. These restrictions aim to prevent electrical hazards and ensure that overcurrent devices remain accessible and safe. Focus on the article that discusses branch circuits and specific configurations like multiwire circuits. 18 / 50 NEC _______ contains the requirements for multiwire branch circuits. a. False b. True Incorrect. The requirements for multiwire branch circuits are covered in NEC Article 210.4, which provides the necessary guidelines for safely installing and protecting these circuits. Correct! NEC Article 210.4 contains the requirements for multiwire branch circuits. NEC Article 210.4 outlines the requirements for multiwire branch circuits, including how to properly size the conductors and ensure that the circuit is protected by an overcurrent device. These circuits are used in certain situations to share a neutral conductor between phases, reducing the number of conductors needed while maintaining electrical safety. Think about the common protective devices used in feeders and branch circuits to ensure quick response in overcurrent situations. 19 / 50 Fast-acting, current-limiting fuses and circuit breakers are generally used for feeders and branch circuits. a. False b. True Incorrect. Fast-acting, current-limiting fuses and circuit breakers are commonly used for feeders and branch circuits to quickly interrupt overcurrent conditions, as specified in NEC Article 240.60. Correct! Fast-acting, current-limiting fuses and circuit breakers are generally used in feeders and branch circuits to provide rapid protection, as required by NEC Article 240.60. Think about the common protective devices used in feeders and branch circuits to ensure quick response in overcurrent situations. Think about the NEC section that governs the sizing of bonding conductors and grounding conductors to ensure they are appropriately rated for their application. 20 / 50 The bonding conductor(s) or jumper(s) must be sized in accordance with which NEC section? a. 250.122 b. 250.60 c. 250.80 d. 250.158 “Incorrect. The correct section is NEC 250.122, which governs the sizing of bonding conductors and jumpers based on the overcurrent protection device.” “Correct! NEC 250.122 specifies the sizing requirements for bonding conductors and jumpers to ensure they are appropriately rated for the system.” NEC 250.122 provides the guidelines for sizing bonding conductors and equipment grounding conductors. The size of these conductors is determined by the rating of the overcurrent protection device. Proper sizing ensures that the conductors can carry fault current without overheating, thereby ensuring the safety of the electrical system. Think about the NEC’s requirement for grounding the neutral conductor at the service entrance. 21 / 50 Is it true that when grounding service-entrance equipment, the identified neutral conductor is the conductor that is required to be grounded, as per NEC 250.26? a. False b. True Incorrect. NEC 250.26 specifies that the identified neutral conductor is the conductor that must be grounded at the service entrance for safety and system reference. Correct! NEC 250.26 requires the identified neutral conductor to be grounded at the service entrance to ensure proper system operation and safety. According to NEC 250.26, the identified neutral conductor is the one that must be grounded in a service-entrance installation. Grounding the neutral conductor ensures that it serves as the return path for unbalanced current and provides a reference for the system’s voltage, contributing to the overall safety of the electrical installation. Consider the relationship between conductor ampacity and overcurrent protection. 22 / 50 Overcurrent protection is sized according to the ampacity of a conductor. a. False b. True Incorrect. Overcurrent protection must be based on conductor ampacity. Correct! Overcurrent protection is sized according to conductor ampacity. NEC 240.4 requires that overcurrent protection devices be sized based on the ampacity of the conductor to prevent overheating and ensure safe electrical system operation. Focus on the fact that only the overcurrent device must be rated for 100% operation, not the enclosure. 23 / 50 Continuous loads are limited to 80% of the overcurrent device’s rating unless the device and enclosure are rated for 100% operation, according to NEC Articles 210.19(A)(1) and 215.2(A)(1). a. False b. True Incorrect. The NEC specifies that continuous loads are limited to 80% of the overcurrent device’s rating unless the device is rated for 100% operation. The enclosure itself does not need to be rated for 100%, making the statement False. Correct! The NEC only requires the overcurrent device to be rated for 100% operation, not the enclosure. Therefore, the statement is False according to NEC Articles 210.19(A)(1) and 215.2(A)(1). According to NEC Articles 210.19(A)(1) and 215.2(A)(1), continuous loads are limited to 80% of the overcurrent device’s rating unless the device is rated for 100% operation. The enclosure does not need to be rated for 100% operation—only the overcurrent device does. This distinction makes the statement False. Consider the conditions under which the metal frame of a building may be used as part of the grounding electrode system. 24 / 50 Is it true that the metal frame of a building is permitted to be used as a grounding electrode conductor? a. False b. True “Incorrect. NEC 250.52(A)(2) permits the metal frame of a building to be used as a grounding electrode if it is properly bonded to the grounding electrode system.” “Correct! The metal frame of a building is permitted to be used as a grounding electrode under NEC 250.52(A)(2), provided it is properly bonded.” According to NEC 250.52(A)(2), the metal frame of a building can serve as a grounding electrode if it is electrically continuous and properly bonded to the electrical system’s grounding electrode system. This provides an effective path for fault current and helps ensure the safety of the building’s electrical system by providing a low-resistance path to earth. Think about the maximum current that a 20-ampere circuit can safely supply to a single appliance without overloading. 25 / 50 A 20-ampere branch circuit is not permitted to serve a single appliance with a rating greater than ____ amperes. a. 18 b. 14 c. 12 d. 16 Incorrect. A 20-ampere branch circuit cannot supply a single appliance with a rating greater than 16 amperes, as specified in NEC Article 210.23(A)(1). Correct! A 20-ampere branch circuit is not permitted to serve a single appliance with a rating greater than 16 amperes, according to NEC Article 210.23(A)(1). According to NEC Article 210.23(A)(1), a 20-ampere branch circuit cannot serve a single appliance with a rating greater than 16 amperes. This limitation ensures that the circuit is not overloaded and operates safely under normal conditions. Consider the NEC rules regarding the number of service disconnects permitted for a service or service-entrance conductors. 26 / 50 Is it true that two to six service disconnects are permitted for each service allowed by 230.2 or for each set of service-entrance conductors allowed by 230.40, Exception No. 1, 3, 4, or 5? a. False b. True “Incorrect. NEC 230.71(A) permits two to six service disconnects for each service allowed by NEC 230.2 or for each set of service-entrance conductors as specified by NEC 230.40, Exception Nos. 1, 3, 4, or 5.” “Correct! NEC 230.71(A) permits two to six service disconnects for each service as allowed by NEC 230.2 or for each set of service-entrance conductors specified by NEC 230.40, Exception Nos. 1, 3, 4, or 5.” According to NEC 230.71(A), two to six service disconnects are permitted for each service as specified by NEC 230.2 or for each set of service-entrance conductors allowed by NEC 230.40, Exception Nos. 1, 3, 4, or 5. This allows for multiple disconnects to be installed in certain situations while maintaining safe control of the electrical service. Consider the standard ampere ratings that are commonly listed in the NEC for both fuses and nonadjustable circuit breakers. 27 / 50 Select all the standard ampere ratings for fuses and nonadjustable circuit breakers. a. 35 b. 10 c. 15 d. 25 e. 20 f. 30 Incorrect. The standard ampere ratings for fuses and nonadjustable circuit breakers include 15A, 20A, 25A, 30A, and 35A, as outlined in NEC Article 240.6(A). Correct! NEC Article 240.6(A) lists 15A, 20A, 25A, 30A, and 35A as standard ampere ratings for fuses and nonadjustable circuit breakers. NEC Article 240.6(A) defines standard ampere ratings for fuses and nonadjustable circuit breakers. Standard ratings include 15A, 20A, 25A, 30A, and 35A, among others, ensuring proper protection for electrical circuits based on load requirements. Think about the point at which service conductors receive overcurrent protection in an electrical system. 28 / 50 Is it true that service conductors do not have overload protection until they reach the main service disconnecting means overcurrent protection? a. True b. False “Incorrect. NEC 230.90(A) specifies that service conductors do not have overload protection until they reach the main service disconnect, where overcurrent protection is provided.” “Correct! According to NEC 230.90(A), service conductors do not have overload protection until they reach the main service disconnecting means.” According to NEC 230.90(A), service conductors are not provided with overcurrent protection until they reach the main service disconnecting means. This is because service entrance conductors are generally unprotected from overloads until they are connected to the main overcurrent protection device at the service equipment. The main service disconnect serves as the point where overcurrent protection is applied to prevent electrical faults from damaging the system. Consider the standard ampere ratings that are commonly listed in the NEC for circuit breakers. 29 / 50 A 55A circuit breaker is considered a standard ampere rating. a. True b. False Incorrect. 55A is not a standard ampere rating for circuit breakers. The NEC specifies that standard sizes include 50A and 60A but not 55A, as per NEC Article 240.6(A). Correct! 55A is not a standard ampere rating for circuit breakers, as outlined in NEC Article 240.6(A). According to NEC Article 240.6(A), circuit breakers and fuses are manufactured in specific standard sizes. 55A is not one of the listed standard ratings; the nearest standard sizes are 50A and 60A. Therefore, a 55A circuit breaker is not considered a standard ampere rating. Think about the NEC’s requirement for a low-impedance path to clear faults and whether the earth alone qualifies as such a path. 30 / 50 Is it true that when grounding service-entrance equipment, the earth is not considered an effective ground-fault current path, as per NEC 250.4(A)(5)? a. True b. False Incorrect. NEC 250.4(A)(5) specifies that the earth is not considered an effective ground-fault current path, as it does not provide a low-impedance route for fault current. Correct! NEC 250.4(A)(5) makes it clear that the earth is not considered an effective ground-fault current path, as a low-impedance path is required. According to NEC 250.4(A)(5), the earth is not considered an effective ground-fault current path because it has a high impedance that prevents sufficient fault current flow to clear a fault. Instead, a low-impedance path, such as the equipment grounding conductor, must be provided to ensure the safe and rapid clearing of ground faults. Consider the devices that are designed to interrupt excessive current in electrical circuits to prevent damage or fire. 31 / 50 Two types of overcurrent protective devices that are commonly used are _______________. a. Fuses b. Panelboards c. Transformers d. Circuit Breakers Incorrect. The two most commonly used overcurrent protective devices are fuses and circuit breakers, not transformers or panelboards, as per NEC Article 240. Correct! Fuses and circuit breakers are the two common overcurrent protective devices, as specified in NEC Article 240. Overcurrent protective devices are essential in electrical systems to prevent damage caused by excessive current. The two most common devices for this purpose are fuses and circuit breakers, as outlined in NEC Article 240. These devices automatically disconnect the electrical supply when a fault or overload occurs, ensuring system safety. Consider the NEC table that provides sizing information for equipment grounding conductors, particularly when overcurrent protection is present. 32 / 50 Which NEC table is referred to when selecting equipment grounding conductors when there is overcurrent protection ahead of the conductor supplying the equipment? a. 250.122 b. 250.102(C) c. 250.66 d. 250.86(A) “Incorrect. NEC Table 250.122 is used for selecting equipment grounding conductors when there is overcurrent protection ahead of the conductor supplying the equipment.” “Correct! NEC Table 250.122 is referred to when selecting equipment grounding conductors based on the size of the overcurrent protection device ahead of the conductor.” NEC Table 250.122 is used to select the appropriate size of equipment grounding conductors based on the rating of the overcurrent protection device ahead of the conductor. This ensures that the grounding conductors are large enough to carry fault currents safely and protect the equipment from electrical hazards. Consider the NEC section that addresses the proper sizing of bonding conductors based on the overcurrent protection device. 33 / 50 The bonding conductor(s) or jumper(s) shall be sized in accordance with which NEC section? a. 250.80 b. 250.158 c. 250.60 d. 250.122 Incorrect. NEC 250.122 outlines the correct sizing requirements for bonding conductors or jumpers based on the overcurrent protection device. Correct! NEC 250.122 specifies the sizing requirements for bonding conductors or jumpers. NEC 250.122 provides the guidelines for properly sizing the bonding conductors or jumpers. The size of these conductors depends on the rating of the overcurrent protection device, ensuring that the bonding system can handle fault currents safely. Look for the industry-standard color-coding used to identify wires in a 277/480V system. 34 / 50 What are the identifying colors for a 277/480V system? a. Brown b. Yellow c. Grey d. Blue e. Black f. Orange g. White h. Red “Incorrect. The standard identifying colors for a 277/480V system are Brown, Orange, Yellow for the phases, and Gray for the neutral. These color codes help ensure safe and proper wiring.” “Correct! The identifying colors for a 277/480V system are Brown (Phase A), Orange (Phase B), Yellow (Phase C), and Gray for the neutral.” In a 277/480V system, it is common practice to use the following colors for phase and neutral wires: Brown for Phase A Orange for Phase B Yellow for Phase C Gray for the neutral wire This color-coding helps to ensure proper identification of the different phases and neutral, reducing the likelihood of wiring errors. Think about the standard interrupting rating that does not require special marking, and when it must be shown on the breaker. 35 / 50 Every breaker having an interrupting rating other than _____ is required to have its interrupting rating shown on the breaker. a. 9000 b. 2500 c. 7500 d. 5000 Incorrect. Breakers with an interrupting rating other than 5000 amps are required to have their interrupting rating shown on the breaker, as specified in NEC Article 240.83(C). Correct! Breakers with an interrupting rating other than 5000 amps must have their interrupting rating displayed, as required by NEC Article 240.83(C). According to NEC Article 240.83(C), any breaker with an interrupting rating other than 5000 amps must have its rating clearly displayed on the breaker. This marking is essential for ensuring that the breaker is suitable for the system’s fault current levels and to avoid damage during overcurrent conditions. Think about the term that refers to grounding non-current-carrying parts of electrical systems for safety purposes. 36 / 50 Which term is defined as normally non-current-carrying conductive materials enclosing electrical conductors or equipment, or forming part of such equipment, that shall be connected to earth to limit the voltage to ground on these materials? a. Grounding Electrode Conductor. b. Grounding, Electrical System. c. Grounding of Electrical Equipment. d. Grounding Electrode. Incorrect. The correct term is ‘Grounding of Electrical Equipment,’ which refers to the grounding of non-current-carrying conductive materials to limit the voltage to ground. Correct! ‘Grounding of Electrical Equipment’ refers to the practice of connecting non-current-carrying conductive materials to earth to limit the voltage to ground. Grounding of electrical equipment refers to connecting non-current-carrying conductive materials, such as enclosures, to the earth. This ensures that the materials do not build up dangerous voltages and helps protect both people and equipment in case of a fault. Consider the need for occupants to have quick access to the circuit breakers that control their specific areas in a commercial building. 37 / 50 The occupants of various businesses in a commercial building must have access to the overcurrent devices for their branch circuits, as per NEC 240.24(B). a. True b. False Incorrect. NEC Article 240.24(B) requires that occupants of commercial buildings must have access to the overcurrent protection devices for their branch circuits to ensure safety and easy maintenance. Correct! NEC Article 240.24(B) states that occupants must have access to the overcurrent protection devices for their branch circuits in a commercial building. According to NEC Article 240.24(B), occupants must have access to the overcurrent protection devices that control their branch circuits. This ensures that they can reset or disconnect circuits as needed for safety or maintenance. Overcurrent devices should be located where occupants can easily reach them without needing specialized access. Consider the NEC’s requirements for grounding in single-phase transformer installations, particularly where the center tap provides a neutral. 38 / 50 Is it true that for single-phase transformers, the center tap of the transformer secondary is required to be grounded? a. False b. True Incorrect. NEC 250.30(A) requires that the center tap of the secondary winding of a single-phase transformer be grounded to provide a neutral and ensure safety. Correct! NEC 250.30(A) requires that the center tap of the secondary winding of a single-phase transformer be grounded, providing a neutral reference point. According to NEC 250.30(A), the center tap of a single-phase transformer’s secondary winding must be grounded to provide a reference point (neutral) for the system. This grounding is essential for safety, as it helps prevent electrical shock and ensures proper operation of the system. Think about the point at which service conductors are provided with overcurrent protection according to NEC. 39 / 50 Is it true that service conductors do not have overload protection until they reach the main service disconnecting means overcurrent protection? a. True b. False Incorrect. NEC 230.90(A) specifies that service conductors do not have overcurrent protection until they reach the main service disconnecting means. Correct! NEC 230.90(A) states that service conductors do not have overload protection until they reach the main service disconnecting means. According to NEC 230.90(A), service conductors do not have overcurrent protection before reaching the main service disconnecting means. The overcurrent protection for the service entrance conductors is provided at the main service disconnect, ensuring that the system is protected from overloads. Consider the 80% rule, which limits the maximum load of an appliance connected to a branch circuit to ensure safety and avoid overloading the circuit. 40 / 50 A 20-ampere branch circuit is not permitted to serve a single appliance with a rating greater than ____ amperes. a. 18 b. 16 c. 14 d. 12 “Incorrect. NEC 210.23(A)(1) specifies that a 20-ampere branch circuit can serve a single appliance with a maximum rating of 16 amperes to prevent overloading.” “Correct! A 20-ampere branch circuit cannot serve a single appliance with a rating greater than 16 amperes, as per NEC 210.23(A)(1).” According to NEC 210.23(A)(1), a 20-ampere branch circuit cannot serve a single appliance with a rating greater than 16 amperes. This rule follows the 80% capacity rule, which ensures that circuits are not overloaded and remain safe during normal operation. The rule is designed to prevent overheating and potential electrical hazards by keeping the load below the circuit’s maximum rating. Think about the limitation imposed on fastened-in-place appliances when sharing a circuit with other appliances. 41 / 50 An appliance is fastened in place, and other cord-and-plug-connected appliances are connected to a 20-ampere branch circuit. What is the maximum allowable load for the appliance that is fastened in place? a. 14 A b. 16 A c. 10 A d. 12 A Incorrect. The maximum allowable load for a fastened-in-place appliance connected to a 20-ampere branch circuit with other appliances is 10 amperes, as per NEC Article 210.23(A)(2). Correct! The maximum allowable load for the fastened-in-place appliance is 10 amperes, according to NEC Article 210.23(A)(2). According to NEC Article 210.23(A)(2), when a fastened-in-place appliance is connected to a 20-ampere branch circuit that also serves other appliances, the maximum allowable load for the fastened appliance is 10 amperes. This prevents the circuit from being overloaded and ensures safe operation. Think about the common limitation for overcurrent protection when dealing with continuous loads to prevent overheating. 42 / 50 Unless the overcurrent device and the equipment that encloses it, such as a panelboard or enclosure, is rated at 100% of its rating, continuous loads are limited to not more than __% of the rating. a. 100 b. 90 c. 80 d. 70 Incorrect. Continuous loads are limited to 80% of the overcurrent device’s rating unless the device and equipment are rated for 100% operation, as per NEC Articles 210.19(A)(1) and 215.2(A)(1). Correct! Continuous loads are limited to 80% of the overcurrent device’s rating unless both the device and enclosure are rated for 100%, according to NEC Articles 210.19(A)(1) and 215.2(A)(1). According to NEC Articles 210.19(A)(1) and 215.2(A)(1), continuous loads must not exceed 80% of the overcurrent device’s rating unless the device and the equipment enclosing it are rated for 100% operation. This limitation ensures the safe operation of electrical systems, especially in environments where loads are sustained for long periods. Continuous load limits are specified unless equipment is rated for full load. 43 / 50 Unless the overcurrent device and the equipment that encloses it, such as a panelboard or enclosure, is rated at 100% of its rating, continuous loads are limited to not more than __% of the rating. a. 100 b. 80 c. 70 d. 90 Incorrect. This percentage does not align with NEC guidelines for continuous loads. Correct! 80% is the limit for continuous loads unless rated for 100%. NEC 210.20(A) mandates that continuous loads should not exceed 80% of the overcurrent device’s rating unless the device and equipment are specifically rated for 100%. Think about the NEC limit on the number of services disconnects that are permitted for a building. 44 / 50 According to NEC 230.71, no more than how many disconnects are permitted to serve as the building service disconnecting means? a. 2 b. 8 c. 4 d. 6 “Incorrect. NEC 230.71(A) permits no more than 6 disconnects to serve as the building’s service disconnecting means.” “Correct! NEC 230.71(A) permits a maximum of 6 disconnects to serve as the building’s service disconnecting means.” NEC 230.71(A) states that no more than 6 service disconnects are allowed to serve as the main disconnecting means for a building. This rule ensures that there are a limited and manageable number of disconnects, providing safety and clarity in situations where the service must be quickly disconnected. Consider the NEC’s requirements for making secure and approved connections for grounding electrode conductors. 45 / 50 Is it true that the grounding electrode conductor is required to be tightly connected using proper lugs, connectors, clamps, or other approved means? a. True b. False Incorrect. NEC 250.70 requires that grounding electrode conductors be securely connected using approved lugs, connectors, clamps, or other listed means to ensure safety. Correct! NEC 250.70 mandates that grounding electrode conductors must be tightly connected using approved means, such as proper lugs, connectors, or clamps. According to NEC 250.70, grounding electrode conductors must be securely connected to grounding electrodes using proper lugs, connectors, clamps, or other approved means. This ensures the electrical continuity and reliability of the grounding system, which is critical for safety and proper system operation. Think about the NEC’s limitation on the number of service disconnects allowed for a building. 46 / 50 NEC 230.71 permits no more than ___ disconnects to serve as the building service disconnecting means. a. 6 b. 2 c. 8 d. 4 Incorrect. NEC 230.71(A) permits a maximum of six disconnects to serve as the building’s service disconnecting means. Correct! NEC 230.71(A) allows for no more than six disconnects to serve as the building’s service disconnecting means. NEC 230.71(A) specifies that no more than six service disconnects are allowed for the building’s main service disconnecting means. This is to ensure a safe and manageable number of disconnect points in the case of an emergency. Consider the NEC table that provides guidance for grounding electrode conductor sizing based on the size of the ungrounded conductors. 47 / 50 Which NEC table is referred to when sizing grounding electrode conductors for services, separately derived systems, and the building or structure disconnecting means? a. 250.122 b. 250.138 c. 250.66 d. 250.49 “Incorrect. NEC Table 250.66 is used for sizing grounding electrode conductors for services, separately derived systems, and building or structure disconnecting means.” “Correct! NEC Table 250.66 is the table referred to when sizing grounding electrode conductors for services, separately derived systems, and building disconnecting means.” NEC Table 250.66 is used to size grounding electrode conductors for various applications, including services and separately derived systems. The table ensures that the grounding electrode conductor is appropriately sized to safely carry fault current to the grounding electrode, thereby protecting the system and ensuring electrical safety. Think about the relationship between the conductor’s ampacity and the need for properly sized overcurrent protection to prevent overheating. 48 / 50 Overcurrent protection is sized according to the ampacity of a conductor. a. True b. False Incorrect. Overcurrent protection must be sized according to the ampacity of the conductor it is protecting to prevent overheating and ensure safe operation, as per NEC Article 240.4. Correct! Overcurrent protection is indeed sized based on the ampacity of the conductor, as required by NEC Article 240.4. According to NEC Article 240.4, overcurrent protection devices, such as circuit breakers and fuses, must be sized according to the ampacity of the conductor they protect. This ensures that the conductor can safely carry the maximum current without overheating or being damaged. Think about the NEC article that deals specifically with grounding and bonding requirements for electrical systems. 49 / 50 The NEC covers grounding and bonding in several articles, but the primary coverage is found in Article ___. a. 250 b. 215 c. 230 d. 100 Incorrect. NEC Article 250 provides the primary coverage for grounding and bonding in electrical systems. Correct! NEC Article 250 is the primary article that covers grounding and bonding requirements. NEC Article 250 covers the requirements for grounding and bonding to ensure electrical systems are properly grounded and bonded for safety. This article details the methods and materials required to protect against electrical faults, reduce shock hazards, and ensure proper system operation. Think about where the neutral conductor should be bonded to the panel enclosure and when it is not allowed. 50 / 50 Is it true that in feeder panelboards, the neutral conductor is not connected to the panel enclosure? a. False b. True Incorrect. In feeder panelboards, the neutral conductor should not be connected to the panel enclosure, as this bonding is only allowed at the main service panel or the first disconnect. Correct! In feeder panelboards, the neutral conductor is not connected to the panel enclosure to prevent parallel current paths. In feeder panelboards, the neutral conductor is not connected to the panel enclosure. This bonding should only occur at the main service panel or first disconnect after a separately derived system to prevent parallel paths for neutral current through the equipment grounding system, which can create safety hazards. Your score is LinkedIn Facebook Twitter 0% Restart quiz Exit Rate & Review Thank you for taking the time to leave us a review! Your feedback is greatly appreciated and helps us improve our services. Send feedback Leave a Reply Cancel replyYour email address will not be published. Required fields are marked * Comment* Name* Email* Website Save my name, email, and website in this browser for the next time I comment. Post Comment