Article 400-490 Part10

This quiz consists of 50 carefully selected questions covering NEC Articles 400 through 490, which provide critical guidelines for flexible cords and cables (Article 400), switchgear and control equipment (Article 409), and installations operating above 1000 volts (Article 490). These sections of the National Electrical Code focus on safety, material specifications, and proper installation practices.

The randomly generated questions ensure a thorough assessment of your understanding, reinforcing key principles related to permitted uses of flexible cords, ampacity ratings, industrial control panels, and high-voltage equipment requirements. Some topics may reappear in different contexts to strengthen comprehension and application.

Your feedback is invaluable! If you notice any discrepancies or have suggestions for improvement, please report them. Your insights help maintain the accuracy and effectiveness of this learning tool.

Think about the electrical characteristics of motors when they first start, particularly inrush current.

1 / 50

The starting current of an electrical motor is very high for a short period of time.

Look for the specific section of the NEC that outlines which types of luminaires are allowed in clothes closets.

2 / 50

The luminaire types permitted in clothes closets are covered in NEC ___.

Look at the definition and requirements for a proper disconnecting means in the NEC. Start-stop and lock-out-stop buttons control the motor but do not physically disconnect power.

3 / 50

Do start-stop and lock-out-stop buttons qualify as a disconnecting means?

Consider the composition of liquid vented and lead-acid batteries.

4 / 50

Liquid vented and lead-acid batteries are built with lead and lead peroxide plates immersed in sulfuric acid.

Look for the NEC requirements for motor circuit switches and the conditions under which horsepower ratings are required.

5 / 50

For most applications, the motor circuit switch required for a motor must be ____.

Think about the specific applications and limitations of fixture wires.

6 / 50

Fixture wires shall not be used for branch-circuit wiring except as permitted in other articles of the code.

Look for the article that specifically addresses lighting fixtures and installations.

7 / 50

The installation of luminaires, lighting outlets, and supports is covered in Article ____ of the NEC.

Think about the stability and safety requirements for lighting installations.

8 / 50

Both the lighting outlet and the luminaire must be supported from a structural member of the building.

Consider the different types of sealed batteries suitable for PV system applications.

9 / 50

What are the two types of sealed batteries used in PV systems?

Think about the specific ratings and markings required for switches used with aluminum conductors.

10 / 50

Snap switches rated ______ or less directly connected to aluminum conductors shall be listed and marked CO/ALR.

Look for the section that details motor protection guidelines.

11 / 50

________ sets forth motor overload protection requirements.

Think about the type of luminaires that are installed within the ceiling rather than on its surface.

12 / 50

__________________ are usually supported by adjustable rails that are attached to the luminaires’ rough-in box.

Think about the primary function of a transformer in an electrical system—adjusting voltage levels for various applications.

13 / 50

Is the principal reason for installing a transformer to either increase or decrease the voltage?

Look for the section that specifies luminaire types for specific locations, like clothes closets.

14 / 50

The luminaire types permitted in clothes closets are covered in NEC _____.

Look for the class of overload relays designed for motors with slow starting characteristics and large amperage ratings.

15 / 50

Class ___ (slow trip) overload relays are used for motors with high inertia loads that are slow to start, as well as for motors rated over 200 amperes.

Consider the conditions under which gassing occurs in batteries.

16 / 50

Gassing occurs during the discharge cycle of a battery.

Find the NEC section that mandates a means for disconnecting certain fluorescent luminaires.

17 / 50

NEC ________ requires a means to be provided for a disconnecting fluorescent luminaires that have double-ended lamps and ballast(s).

Consider the typical discharge range for deep cycle batteries.

18 / 50

A deep cycle battery is designed to be discharged until ____________________% of its capacity is used.

The life expectancy of a motor decreases significantly with an increase in temperature. Consider the rule of thumb related to thermal damage for motor

19 / 50

For each 10 degrees Celsius increase above the maximum temperature rating of a motor, the motor’s expected life is reduced by ____.

Think about what the overcurrent device is meant to protect in the circuit connected to the transformer.

20 / 50

According to NEC 450.3, the overcurrent device protects the ___________ only.

Consider the temperature requirements for conductors in luminaires.

21 / 50

Branch circuit conductors that terminate in luminaires have an insulation suitable for the temperature encountered.

Consider the specific NEC exception for switch loops.

22 / 50

When grouping conductors of switch loops in the same raceway, it is not required to include a grounded conductor.

Consider the different stages involved in battery charging.

23 / 50

The three stages of battery charging are bulk charging, absorption charging, and trickle charging.

Consider the role of primary high-voltage metering in monitoring electrical consumption in commercial buildings.

24 / 50

What is the purpose of the primary high-voltage metering in commercial buildings?

Consider the concept of electrolyte stratification in batteries.

25 / 50

In a stratified battery, the performance diminishes where the specific gravity of the electrolyte is greater at the bottom of the battery than at the top of the cell.

Consider common ratings for fused disconnect switches.

26 / 50

A standard fused disconnect ampere rating is 30 amperes.

Consider the load limitations for safety and equipment longevity.

27 / 50

Alternating-current or direct-current general-use snap switches may be used for control of inductive loads not exceeding ______ percent of the ampere rating of the switch at the applied voltage.

Consider the height requirements for exposed terminals in cleat-type lamp holders.

28 / 50

Cleat-type lamp holders located as least _ ft above the floor shall be permitted to have exposed terminals.

Consider the description of the conductors between the utility supply system and the service point as mentioned in the provided text.

29 / 50

What are the underground conductors between the utility electric supply system and the service point commonly referred to as?

Consider the function of overload relays compared to contactors when it comes to motor protection.

30 / 50

Overload contactors are the most common form of motor overload protection.

Consider the description of the installation type that is suitable for smaller service-entrance requirements and provides weatherproof enclosure for the transformer and metering equipment.

31 / 50

Which type of transformer installation is particularly adapted to smaller service-entrance requirements and encloses both the transformer and metering equipment in a weatherproof cabinet?

Consider whether NEC allows any luminaire to be used as a raceway for conductors.

32 / 50

Any luminaire is permitted to be used as a raceway.

Consider which section of the NEC specifically addresses the installation requirements for luminaires and lighting outlets.

33 / 50

The installation of luminaires, lighting outlets, and supports is covered in Article ___.

Consider the type of switch required for motor circuits that must account for the specific operational demands, such as starting and running currents.

34 / 50

In most applications, the motor circuit switch for a motor is required to be ____.

Consider the calculation of battery capacity based on discharge rate.

35 / 50

What is the capacity in amp-hours of a battery that can deliver 2 amps for 50 hours?

The correct type of switch must be able to serve as both the motor controller and the disconnecting means for small motor applications like an exhaust fan.

36 / 50

According to NEC 430.111, a _______ snap (toggle) switch can serve as both the controller and the required disconnecting means for an exhaust fan.

Find the section of the NEC that specifies how luminaires should be supported in suspended ceilings.

37 / 50

The means of support for luminaires in suspended ceilings is covered in ____.

Consider safety regulations for wiring through luminaire outlet boxes.

38 / 50

Branch circuit wiring is not permitted to be passed through an outlet box that is an integral part of an incandescent luminaire unless the luminaire is identified for use.

When looking at motor circuit switches, think about what ratings would be critical for ensuring the proper operation and safety of the switch, especially in terms of electrical characteristics.

39 / 50

The nameplate on all motor circuit switches, along with the manufacturer’s technical data, provides the horsepower rating, the _______ rating, and the ampere rating of the disconnect switch.

Consider the purpose of equalizing charging in maintaining battery health.

40 / 50

____________________ charging is designed to produce consistency between all of the various cells in a battery bank.

Consider the definition and function of electrolyte in batteries.

41 / 50

The ____________________ is the liquid conductor of electricity in a battery in which current flow takes place and is caused by the migration of charged articles called ions.

Consider the classification of motor controllers that allows for some level of damage as long as it remains functional.

42 / 50

Which type of controller allows a certain amount of damage, such as welding of the contacts or burning out of the overload relays, to be considered acceptable?

Consider the function of a termination box in organizing and securing connections of service conductors.

43 / 50

What is the primary purpose of a termination box at a service installation?

Think about the methods used to protect cables from abrasion when passing through enclosures.

44 / 50

Flexible cords and cables shall be protected by __________ where passing through holes in covers, outlet boxes, or similar enclosures.

Consider the limit on the number of disconnects permitted for the building service disconnecting means as outlined in NEC regulations.

45 / 50

According to NEC Article 230.71, how many disconnects are permitted to serve as the building service disconnecting means?

Consider the common setup of panelboards in commercial settings where all components come together for convenience and efficiency.

46 / 50

In commercial applications, “enclosed panelboards” are typically installed. These enclosed panelboards include the cabinet, panelboard interior, and cover, all provided in one carton. Is this statement true or false?

Consider what type of protection is necessary on the secondary side of a transformer to prevent electrical hazards.

47 / 50

According to NEC 408.36(B), panelboards supplied through a transformer must have ________________ on the secondary side of the transformer.

Consider the transformer connection scheme commonly used in commercial buildings and its advantages for power distribution.

48 / 50

Which type of transformer connection is commonly used for modern commercial buildings and allows for connection of lighting or other line-to-neutral loads?

Consider the specific applications for different types of general-use switches.

49 / 50

General-use __________ switches shall be used only to control permanently installed incandescent luminaires unless listed for the control of other loads and installed accordingly.

Portable generators are categorized by their output capacity.

50 / 50

The NEC covers portable generators through __ kW separately from those larger than __ kW.