What you’ll learn
After this post, you will be able to explain specific gravity, use a hydrometer to read it, and estimate a lead-acid battery’s state of charge from the reading.
First, six words
A voltaic cell is a combination of materials that converts chemical energy into electrical energy — two electrodes of different metals or metallic compounds placed in an electrolyte solution. A battery is a group of two or more connected voltaic cells, so a single cell is not, strictly, a battery in this handbook’s usage. An electrode is a metallic compound or metal with an abundance of electrons (negative electrode) or an abundance of positive charges (positive electrode). An electrolyte is a solution capable of conducting electric current; it may be liquid or paste — paste means a dry cell, solution means a wet cell. And an ampere-hour is one ampere flowing for one hour: ampere-hours = current × time, the usual way to state how much energy a storage battery can deliver.
Specific gravity: weighing the acid
Specific gravity is the ratio of the weight of any liquid to the weight of an equal volume of water. Pure water is 1.000; pure sulfuric acid is 1.835. A lead-acid electrolyte — water mixed with sulfuric acid — therefore falls between 1.000 and 1.835, and is normally mixed to less than 1.350. Why does that matter? Because discharging a lead-acid battery consumes acid and makes water, so the electrolyte gets lighter; charging drives the acid back, so it gets heavier again. The decrease in specific gravity on discharge is proportional to the ampere-hours discharged, so a hydrometer reading is an approximate state-of-charge indicator.
The hydrometer
A hydrometer is a weighted, sealed glass float with a specific-gravity scale along its body, inside a glass tube. Test fluid is drawn into the tube, the float sinks to a level, and the scale reading at the fluid surface is the specific gravity. Simple, no power needed, and it reads the chemistry directly rather than the voltage.
The worked example: 71% discharged
Worked example from the handbook: the reading is 1.175; the full-charge average is 1.260; and the normal gravity drop is 120 points (0.120) at an 8-hour discharge rate. The battery is 85 points below full charge, so 85 / 120 is about 71% discharged — roughly 29% remaining. The method: compare the reading with the full-charge value and the manufacturer’s published specific-gravity drop from full to nominal, for that battery and discharge rate. The rise on charge is not uniform or proportional to ampere-hours charged, so the reading is approximate — a usable field check, not a laboratory measurement.
Common mistakes
- “A single cell is a battery.” Not in this handbook’s usage. A battery is a group of two or more connected voltaic cells.
- “Voltage alone tells me the state of charge.” Voltage sags under load and recovers at rest. Specific gravity reads the chemistry directly, which is why the hydrometer is the field instrument.
- “The hydrometer gives an exact state of charge.” It gives an approximate one. The drop on discharge is proportional to ampere-hours discharged, but the rise on charge is not uniform — always compare against the manufacturer’s full-charge and drop figures for that battery.
- “Specific gravity 1.000 means the battery is empty.” It means the liquid weighs the same as water — pure water is 1.000, pure sulfuric acid is 1.835, and a lead-acid electrolyte sits between them.
Summary
Specific gravity weighs the acid against water: water is 1.000, pure sulfuric acid is 1.835, and a lead-acid electrolyte sits between them, normally under 1.350. Discharging consumes acid and makes water, so the reading falls; charging reverses it. Draw fluid into a hydrometer, read the scale at the surface, and compare with the full-charge value and the manufacturer’s normal drop — 1.175 against a 1.260 full charge and a 120-point drop means about 71% discharged.
Quick-check questions
- What is a battery, in this handbook’s usage?
- What is specific gravity?
- What is a hydrometer, and how do you read it?
- Why does specific gravity fall as a lead-acid battery discharges?
- A reading of 1.175, full charge 1.260, normal drop 120 points — how discharged is the battery?
Answers: 1. A group of two or more connected voltaic cells. 2. The ratio of the weight of any liquid to the weight of an equal volume of water. 3. A weighted, sealed glass float with a specific-gravity scale inside a glass tube; draw test fluid in and read the scale at the fluid surface. 4. Because discharging consumes acid and produces water, so the electrolyte gets lighter. 5. About 71% discharged (85 / 120).
Based on DOE-HDBK-1011/92, Electrical Science, Module 4, paraphrased for study.
Video lesson for this module is in production — coming soon.
Quiz for this module is being prepared.
Flashcards for this module are being prepared.
- Tags:
- VOL2