Understanding NEC Article 396: Messenger-Supported Wiring

Introduction

NEC Article 396 addresses the installation and use of messenger-supported wiring systems, which are employed to support electrical conductors using a messenger wire. These systems are particularly useful in industrial environments, commercial spaces, and select residential installations, providing efficient and organized power distribution where conventional conduit systems may not be practical.


Scope

This article applies to messenger-supported wiring systems and outlines the specific requirements for their construction, installation, and permitted applications. The messenger wire acts as a support structure for conductors and, in some cases, can serve as a neutral or equipment grounding conductor.


Permitted and Prohibited Uses

Permitted Uses:
  1. Cable Types:
    • A variety of cables, including medium-voltage, metal-clad (MC), mineral-insulated, service-entrance, and tray cables, as listed in Table 396.10(A).
  2. Industrial Settings:
    • Suitable for industrial establishments with conditions ensuring only qualified personnel service the wiring.
  3. Hazardous Locations:
    • Permitted in classified hazardous areas when cables and wiring systems meet specific NEC requirements.
Prohibited Uses:
  1. Hoistways:
    • Not allowed in hoistways or similar spaces.
  2. Physical Damage:
    • Cannot be installed in locations where they may be subject to physical damage.

Installation Guidelines

  1. Messenger Support:
    • Messenger wires must be securely supported at dead ends and intermediate points to prevent tension on the conductors.
    • Conductors must not contact messenger supports, structural members, walls, or pipes.
  2. Grounding:
    • When the messenger serves as a grounding conductor, it must comply with specific grounding requirements in Article 250.
    • Grounding connections must ensure electrical continuity and meet safety standards.
  3. Neutral Conductor Use:
    • If used as a neutral conductor, the messenger must meet the provisions in 225.4, 250.184(A), and related sections.
  4. Splices and Taps:
    • Conductor splices and taps must be made using approved methods and insulated accordingly to maintain system safety.
  5. Weather Exposure:
    • Conductors must be suitable for wet locations and resistant to sunlight if exposed to the elements.

Special Considerations

  1. Support Design:
    • The support structure for messenger wires should minimize conductor sag and maintain tension within safe limits.
  2. Environmental Factors:
    • Installations in corrosive or extreme environments may require additional protective measures for both the messenger and conductors.

Applications

  1. Industrial Environments:
    • Frequently used in manufacturing facilities to distribute power efficiently across large spaces.
  2. Utility Systems:
    • Supports the routing of medium-voltage power cables for service drops and feeder lines.
  3. Commercial Spaces:
    • Useful in areas requiring overhead power distribution without rigid conduits.

Compliance Tips

  1. Follow NEC Specifications:
    • Ensure all components and installations meet the requirements outlined in Article 396.
  2. Inspect for Damage:
    • Regular inspections should be conducted to identify wear, damage, or potential safety hazards.
  3. Use Approved Materials:
    • Select materials listed and rated for messenger-supported wiring systems to ensure durability and compliance.

Conclusion

Messenger-supported wiring systems offer a practical solution for various electrical installations, particularly in industrial and utility applications. NEC Article 396 provides essential guidelines to ensure these systems are safe, efficient, and compliant with modern electrical standards.