What you’ll learn
After this post, you will be able to describe what is inside a squirrel-cage rotor and a wound rotor, explain how each one gets its rotor current, and say which one to pick for a given job.
Two rotors, one stator
Every induction motor has the same stator — three windings making a rotating magnetic field. What differs is the rotor, the spinning part inside. There are two kinds, and the difference decides what the motor can do: the squirrel-cage rotor, which is a solid piece of metal with no wires at all, and the wound rotor, which is a wound coil connected to the outside world through slip rings and brushes. Same stator, same rotating field, two very different rotors.
The squirrel-cage rotor: bars and rings, nothing else
The squirrel-cage rotor is a laminated steel cylinder with slots around its outside. Into those slots go heavy copper bars, and each end of the bars is joined by a copper or brass end ring — so the bars and rings form a closed cage, like the exercise wheel of a squirrel (that is where the name comes from). There is no insulation between the bars and the core, because the voltages induced in the rotor are low. There are no wires, no connections, nothing to wear out. The air gap between rotor and stator is kept small, so the magnetic field is as strong as possible. When the rotating stator field sweeps past the bars, current is induced in the closed cage, the cage makes its own field, and the rotor chases the stator field. That is the whole machine — simple, rugged, cheap, and the most common industrial motor in the world. Its weakness is that you cannot reach into it: the rotor circuit is fixed, so its starting torque and speed are fixed by its construction.
The wound rotor: coils you can reach
The wound rotor is built the other way: instead of bars, its slots hold coils of wire, wound like a stator winding, and the ends of those coils are brought out through slip rings and brushes to terminals outside the motor. Through those terminals you can connect external resistors into the rotor circuit. That one difference changes everything. Add resistance to the rotor at starting, and the starting torque rises while the starting current falls — the motor starts a heavy load gently instead of slamming it. As the motor speeds up, you cut the resistance out step by step until the rotor is shorted, and the motor runs like a squirrel-cage machine. You can also use the external resistance to control the speed: more rotor resistance means more slip, and more slip means a slower motor under load. The price is complexity: slip rings and brushes wear, need maintenance, and cost more — and the motor is bigger and more expensive for the same power.
Side by side
- Construction: squirrel-cage — copper bars and end rings, no insulation, no connections; wound rotor — coils in slots, connected out through slip rings and brushes.
- Starting: squirrel-cage — fixed starting torque (150–200% of full load) and high starting current; wound rotor — high starting torque with low starting current, adjustable with external resistance.
- Speed control: squirrel-cage — essentially fixed speed (slip of a few percent); wound rotor — speed can be varied by changing the external rotor resistance.
- Maintenance: squirrel-cage — almost none, nothing to wear; wound rotor — brushes and slip rings need regular attention.
- Cost: squirrel-cage — cheap, rugged, the default choice; wound rotor — more expensive, used only where its control is worth it.
- Applications: squirrel-cage — most industrial work generally, pumps, fans, conveyors running at steady speed; wound rotor — cranes, hoists, and mills where heavy loads must start smoothly and speed must vary.
The worked example: two jobs, two motors
Job 1 — a water pump that runs all day at one speed. The load is steady, the starting torque needed is modest, and nobody will maintain it often. Pick the squirrel-cage motor: cheap, rugged, no brushes to wear, and it will run for years with almost no attention.
Job 2 — a crane hoist that must lift a heavy load from a standstill, start smoothly without jerking, and run at different speeds for precise positioning. A squirrel-cage motor would slam the load with high starting current and fixed speed. Pick the wound-rotor motor: external resistance gives high starting torque with low starting current, and varying the resistance varies the speed — exactly what a hoist needs, and worth the brushes, the maintenance, and the higher price.
Common mistakes
- “The squirrel-cage rotor has windings.” It does not — it has solid copper bars joined by end rings. The wound rotor is the one with coils.
- “A wound rotor is just a bigger squirrel-cage.” It is not — it is a different construction with slip rings, brushes, and external terminals, and it behaves differently at starting and at varying speed.
- “Slip rings are only for synchronous motors.” They are not — wound-rotor induction motors use slip rings too, to bring the rotor circuit out to external resistors.
- “More rotor resistance always means a worse motor.” It does not — added rotor resistance raises starting torque and lowers starting current, and lets you control speed. It is a tool, not a defect.
- “A squirrel-cage motor can be speed-controlled the same way.” It cannot — its rotor circuit is sealed inside, so you cannot add resistance to it. Its speed is set by the supply frequency and the pole count.
- “The wound rotor is always the better motor.” It is not — it costs more, needs brush maintenance, and is bigger. For a steady-speed job the squirrel-cage motor is the better choice.
- “The air gap doesn’t matter.” It does — a small air gap gives maximum field strength, and both rotor types are built with the gap as small as practical.
Summary
An induction motor’s stator is the same either way; the rotor is where the choice lives. The squirrel-cage rotor is copper bars and end rings — no wires, no insulation, no maintenance, fixed starting torque and fixed speed, cheap and rugged, the default for most industrial work. The wound rotor is coils brought out through slip rings and brushes, so external resistance can raise starting torque, cut starting current, and vary speed — at the price of maintenance and cost, for jobs like cranes and hoists that need it. Pick the cage for steady work; pick the wound rotor when starting and speed control matter more than simplicity.
Quick-check questions
- What is a squirrel-cage rotor made of?
- What is a wound rotor, and how does it connect to the outside world?
- How does external rotor resistance change starting torque and starting current?
- How can a wound-rotor motor’s speed be varied?
- Which rotor would you pick for a crane hoist, and why?
Answers: 1. A laminated steel cylinder with heavy copper bars in its slots, joined at each end by a copper or brass ring — no insulation, no wires, no connections. 2. Coils of wire in the rotor slots, whose ends are brought out through slip rings and brushes to external terminals, where resistors can be connected. 3. Adding resistance to the rotor at starting raises the starting torque and lowers the starting current. 4. By changing the external rotor resistance — more resistance means more slip, and more slip means a slower motor under load. 5. The wound rotor — external resistance gives high starting torque with low starting current for a smooth start, and varying the resistance varies the speed for precise positioning.
Based on DOE-HDBK-1011/92, Electrical Science, Module 12, paraphrased for study.
Top 10 Scorers
| Pos. | Name | Score | Duration |
|---|---|---|---|
| There is no data yet |
What is a squirrel-cage rotor?
A laminated steel cylinder with heavy copper bars in its slots, joined at each end by a copper or brass ring
Question Explanation:
The squirrel-cage rotor is a laminated cylinder with slots holding heavy copper bars joined at each end by a copper/brass ring. No insulation is needed between core and bars because induced rotor voltages are low.
Why is no insulation needed between the squirrel-cage bars and the core?
Because the voltages induced in the rotor are low
Question Explanation:
No insulation is needed between core and bars because induced rotor voltages are low.
What is a wound rotor?
A rotor with coils of wire in its slots, whose ends are brought out through slip rings and brushes to external terminals
Question Explanation:
The wound rotor has coils in its rotor slots, fed via slip rings and brushes, with the coil ends brought out to terminals outside the motor where external resistors can be connected.
What does adding external resistance to a wound rotor do at starting?
It raises the starting torque and lowers the starting current
Question Explanation:
Add resistance to the rotor at starting, and the starting torque rises while the starting current falls — the motor starts a heavy load gently instead of slamming it.
How can a wound-rotor motor's speed be varied?
By changing the external rotor resistance — more resistance means more slip, and more slip means a slower motor under load
Question Explanation:
You can use the external resistance to control the speed: more rotor resistance means more slip, and more slip means a slower motor under load.
What is the main maintenance difference between the two rotors?
The wound rotor's slip rings and brushes wear and need regular attention; the squirrel-cage rotor has almost nothing to wear
Question Explanation:
The price of the wound rotor's control is complexity: slip rings and brushes wear, need maintenance, and cost more. The squirrel-cage rotor has no wires, no connections, nothing to wear out.
Which rotor is the most common industrial AC motor, and why?
The squirrel-cage rotor — simple, rugged, relatively low cost, with a self-contained rotor and no external connections
Question Explanation:
The induction motor is the most common industrial AC motor because of its simplicity, rugged construction, and relatively low manufacturing cost — the rotor is self-contained with no external connections.
In the worked example, which motor is picked for a water pump that runs all day at one speed, and why?
The squirrel-cage motor — cheap, rugged, no brushes to wear, and it will run for years with almost no attention
Question Explanation:
For a water pump that runs all day at one speed, with a steady load and modest starting torque, the squirrel-cage motor is the pick: cheap, rugged, no brushes to wear, running for years with almost no attention.
In the worked example, which motor is picked for a crane hoist, and why?
The wound-rotor motor — external resistance gives high starting torque with low starting current and variable speed for precise positioning
Question Explanation:
A crane hoist must lift a heavy load from a standstill, start smoothly without jerking, and run at different speeds for precise positioning. The wound-rotor motor's external resistance gives high starting torque with low starting current, and varying the resistance varies the speed — exactly what a hoist needs.
- Tags: